Troubleshooting

symptom
x
x
x
x
x
x
x
x
x x
x
x
x
x
x
x
x
x
x
x
x
x
2530GA(P)
possible cause
High tension lead loose
HT lead shorting out on burner body
Electrode broken
Faulty piezo-igniter
No gas
Air in tubes
x
Gas pressure too high
x
Gas pressure too low
x
Pilot jet or tubing blocked
Incorrect pilot jet
Thermocouple insufficiently hot
x
Thermocouple not in pilot flame
Sooting of thermocouple
x
Faulty thermocouple
x
Faulty safety valve
x
Blocked tubing or main nozzle
x
Thermocouple interrupter or leads too loose
x
Faulty contact on TTB (clixon)
Burr on main nozzle
Partly blocked burner
Gas leak
x x
Blocked chimney, too low chimney draught Control and clean (*)
x
Appliance is leaking
x
Dust on appliance
x
Batteries
x
Wiring from receiver to gas block
x
Sender or receiver broken
- 42 -
possible remedy
(*) = must be carried out by
qualified engineer
Check connection (*)
Establish where spark is occuring and insulate
or re-route lead accordingly (*)
Replace electrode (*)
Replace piezo (*)
Open gas supply
Be patient until air is replaced by gas
Re-adjust supply pressure or call gas -supply
company (*)
Check for possible obstruction of gas supply
tube, re-adjust supply pressure or call gas -
supply company (*)
Clean tubes or pilot nozzle (*)
Place correct pilot nozzle (*)
Wait a moment to heat thermocouple
Put thermocouple in correct position(*)
Clean thermocouple
Replace thermocouple (*)
Replace safety valve (*)
Clean tubes and main nozzle (*)
Fix thermocouple interrupter and/or check
leads
Replace TTB (*)
Remove burr (*)
Clean burner (*)
Look up leak and rectify (*)
Look up and rectify (*)
Remove dust
Replace
Check for eventuel bad contact and repair
Replace
03.27603.000