Command and control electronics
Description
The control panel is powered at 24 V AC.
The control devices and accessories are powered at 24 V. Careful! The accessories must not exceed 10 W overall.
All connections are quick-fuse protected.
Functions on input and output contacts and time and user management details, are set up and viewable on the
software-managed control panel's display.
⚠ Warning! Before intervening on the control panel, cut off the main power supply.
Line fuse
Accessories fuse
Control unit fuse
Main components
1 Programming buttons
2 Programming warning LED
3 Memory roll card connector
4 R700 card connection of the first control device
5 R700 card connection of the second control device
6 Display
7 Control devices or paired connection terminals
8 Warning devices temrinals
9 Connector for LED luminous band
10 Transponder terminals
11 Control devices terminals
12 Accessories power supply terminals
13 Control board power supply terminals
14 Accessories fuse
15 Control board fuse
16 Motor connector/encoder
17 LED power on warning
18 Line fuse
18
Warning LED
Green LED
Red LED
Blue LED
FUSE TABLE
1.6 A-F (230 V)
3.15 A-F (120 V)
1 A-F
630 mA-F
Flashing
Turned on
steady
Slow fl ashing
Quick fl ashing
Flashing
7
4
5
6
1
17
16
Leaf/leaves opening
Stand-by
Leaf/leaves closing
Prefl ashing time before the leaf closing phase
Stop button (N.C. contact)
Automatic closing time
11
12
13
9
8
10
2
3
14
15