CONNECTING TWO COUPLED GEARMOTORS HAVING A SINGLE CONTROL
With two coupled gearmotors, you can command only the opening (by button and/or radio control): the gate will close only in automatic closing mode.
Coordinate the direction of travel of the two gearmotors and , by modifying the motor's rotation (invert the cables on terminals FA-FC and U-V).
Make the electrical connections only on the motor's control board . Whereas, the adjustments and features, must be made on both boards.
Connect the two boards together, as illustrated. Set DIP 1 and 3 to ON on both boards.
Fit the AF board only into the gearmotor's board .
The transmitter button for opening a gate must be memorized on the gearmotor's channel CH1 . The transmitter button for opening both gates must be
memorized on the gearmotor's channel CH2 .