Oceanic OCEACLIM120W Mode D'emploi page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fuse parameters of the machine
T
ype: 5ET or SMT
Voltage: 250V
A. Unit Storage:
1:Unscrew the drainage cover, unplug the water plug, and discharge the water in the water pan into other water containers or directly
tilt the body to discharge the water into other containers.
2:Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to
keep the inside of the body in a dry state and prevent it from mildewing.
3:Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the water plug and the
drainage cover.
4:Remove the exhaust pipe and keep it properly.
5:Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it out of the reach of children, and take
dust control measures.
6:Remove batteries of the remote control and keep them properly.
Note: ensure that the body is placed in a dry place and keep all machine components properly.
IX.Troubleshooting
Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the
warranty card, and may cause damage to users or their properties.
Problems
Reasons
There is no electricity.
The overflow indicator displays "FL".
The ambient temperature is too low or too high
The air conditioning
In cooling mode, the room temperature is
does not work.
lower than the set temperature; in heating
mode, the room temperature is higher than the
set temperature.
In
temperature is low.
There is direct sunlight.
Doors or windows are open; there are a lot of
people; or in cooling mode, there are other
The cooling effect is
sources of heat.
not good
The filter screen is dirty.
The air inlet or outlet is blocked.
The air conditioning is not placed on a flat
Big Noise
surface.
Current: 3.15 A
dehumidification
mode,
Solutions
Turn it on after connecting it to a socket with electricity.
Discharge the water inside.
Recommend to use the machine in at the temperature
of 7-35 ℃ (44-95 ℉).
Change the set temperature.
the
ambient
The machine is placed in a room with an ambient
temperature of greater than 17 ℃ (62 ℉).
Pull the Curtain.
Close doors and windows, and add new air
conditioning.
Clean or replace the filter screen.
Clear obstructions.
Put the air conditioning on a flat and hard place (to
reduce noise).
17

Publicité

Table des Matières
loading

Table des Matières