• If the laser is dropped or has suffered a sharp blow, have the
GB
calibration system checked by a qualified service center before
using the laser.

Turning the Laser On

1.
Insert the fully charged D
Figure
.
D
2.
Gently press the power button
• The power LED indicator light (Figure
• Self-leveling mode is activated automatically and the laser unit
will self-level. Once the laser unit is level, the beam will rotate
clockwise once at 600RPM.
• 30 sec. after the last button press, HI Mode (Height of
Instrument, Anti-Drift) is activated automatically and the HI LED
(Figure
) will illuminate. (You can disable HI Mode by
A 2
holding down the Slope Mode button
will beep twice and the HI Mode LED will turn off. NOTE: when
HI Mode is disabled, the laser cannot detect any movement
after setup, so accuracy cannot be guaranteed.)
Press
(Figure
3.
A
laser beam through its 4 preset speeds (150, 300, 600, and
1200 RPM). NOTE: Accuracy is best optimized at 600 RPM or
less.
To change the Direction of the laser beam while in self-leveling
4.
mode, press
or
5.
Press the Scan Mode button
to scan in 0°, 15°, 45°, or 90° angle mode.
15˚/45˚/90˚
is used to make the laser head sweep back and forth,
creating a short, bright laser line. This short line is much
brighter and more visible than when the unit is in full rotation
mode.
• The direction of the scan zone can be controlled with the arrow
buttons
and
16
WALT 18V battery pack as shown in
E
to power ON the laser:
) will illuminate.
A 3
for 2 secs. The laser
) to adjust the Rotation Speed of the
16
(Figure
or
).
A
18
19
15˚/45˚/90˚
(Figure
) to set the laser
A
17
(Figure
or
)
A
18
19
If you press the Slope Mode button
6.
the unit automatically engages the X-Axis. This allows you to
slope the laser in the direction of the X-Axis, as indicated by the
X mark on the top roll cage.
• In certain situations, it may be desirable to slope the laser in
the Y-axis. The direction of Slope Mode can be changed back
and forth between the Y-axis and the X-axis by pressing the
X-Y axis button
(Figure
• If using X-axis leveling, the X-axis LED (Figure
or if using Y-axis leveling, the Y-axis LED (Figure
light instead.
7.
When in Slope Mode, press
and down (adjust the elevation of the laser beam).
• Each quick press of
(1/16" @ 30ft. or 1.6mm @ 10m).
• If you press and hold
slope will move from 0.01º/sec to 0.2º/sec.
• If you press and hold
move 0.2º/sec.
8.
To turn off the laser unit, press and hold the power button
3 secs.
BEFORE using the laser for your first project, follow the
9.
instructions for Checking the Calibration.
NOTE: When you press the Slope Mode button
will return to self-level mode.

Checking the Calibration

Field calibration checks should be done frequently. This section
provides instructions for performing simple field calibration checks of
your D
WALT Rotary Laser. Field calibration checks do not calibrate
e
the laser. That is, these checks do not correct errors in the leveling
or plumb capability of the laser. Instead, the checks indicate whether
or not the laser is providing a correct level and plumb line. These
checks cannot take the place of professional calibration performed
by a D
WALT service center.
e
to turn ON Slope Mode,
).
A
13
) will light,
A
15
A
14
or
to tilt the laser head up
or
will move the slope by 0.01º
or
between 2 sec - 10 sec, the
or
longer than 10 sec, the slope will
again, the laser
) will
for

Publicité