8

Technical data

The specifications are typical values at room temperature.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
8.1

Accuracy

Resolution
10 μm, 50 μm, 100 μm,
(with 4x evaluation)
500 μm, 2500 μm
Repeat accuracy
< 1 increment
System accuracy
Accuracy class I
±400 µm (working range)
Accuracy class II
Typ. ±550 µm (function range)
8.2

Ambient conditions

Operating temperature
–20°C to +80°C
Storage temperature
–30°C to +85°C
Shock rating
100 g/6 ms
per EN 60068-2-27
2)
Continuous shock
100 g/2 ms
per EN 60068-2-29
2)
Vibration load
12 g, 10 to 2000 Hz
per EN 60068-2-6
2)
Degree of protection per
IP67
IEC 60529 (when plug is
attached)
External magnetic fields –
Relative humidity
< 90%, non-condensing
www.balluff.com
1)
< 30 mT (to avoid
permanent damage)
< 1 mT (to avoid influencing
the measurement)
8.3

Supply voltage

Supply voltage
5 V ±5% (only ...Q6_...)
3)
10 V to 30 V (only ...Q5_...)
Current draw
Reverse polarity
Yes, only with supply voltage
protection
10 to 30 V (BML-S...-Q5...)
Overvoltage protection
No
Switch-on delay (system
≤ 500 ms
ready) after applying
supply voltage
8.4

Output

Output signals
See Tab. 4-1 and Tab. 4-2
Output circuit
8.5

Dimensions, weights

Housing geometry
10x25x35 mm
(W x H x L)
Weight (sensor head)
11 g (without cable)
Material (housing)
PBT
(plastic, glass fiber reinforced)
Magnetic tape
10.5×10
temperature coefficient
(like steel)
For
: Use in enclosed spaces and up to a height of 2000 m above
1)
sea level.
Individual specifications as per Balluff factory standard
2)
For
: The sensor head must be externally connected via a
3)
limited-energy circuit as defined in UL 61010-1, a low-power source as
defined in UL 60950-1 or a class 2 power supply as defined in UL 1310
or UL 1585.
< 100 mA + controller
current draw (depending
on internal resistance), at
5 V supply voltage
< 80 mA + controller
current draw (depending
on internal resistance), at
10 V to 30 V supply voltage
HTL
(push-pull, only ...-Q53...)
RS422 (Line Driver)
K
-6
-1
english
15