Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Control Signals - Balluff BTL5-S1 B-M Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL5-S1_ _B-M_ _ _ _-HB/WB-FA_ _/F_ _-C
Linear Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1014-2R or BTL-P-1012-4R:
Resolution (LSB)
depending on version:
BTL5-S1 _1...
1 µm
BTL5-S1 _2...
5 µm
BTL5-S1 _3...
10 µm
BTL5-S1 _4...
20 µm
BTL5-S1 _5...
40 µm
BTL5-S1 _6...
100 µm
BTL5-S1 _7...
2 µm
BTL5-S1 _8...
50 µm
Non-linearity
for resolution < 10 µm
for resolution > 10 µm
Output data
The maximum sampling frequency
f
at which each sample provides a
A
new actual value can be determined
from the following table:
[mm]
Nom. length
< 100
Nom. length
< 1000
Nom. length
< 1400
Nom. length
< 2600
Nom. length
< 4000
Fig. 8-1: Diagram
Hysteresis
Repeatability
(resolution + hysteresis)
Temperature coefficient
< (6 µm + 5 ppm * nominal length)/K
lag error
2.5 Frame
Shock loading
100 g/6 ms
per EN 60068-2-27
1
Continuous shock
100 g/2 ms
per EN 60068-2-29
1
Vibration
12 g, 10 to 2000 Hz
1
per EN 60068-2-6
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a
hydraulic cylinder
1
Individual specifications as per
Balluff factory standard
8.1
Dimensions, weights,
ambient conditions
Nominal length
Dimensions
Weight
Housing/Flange
Pressure tube
Diameter
Wall thickness
± 30 µm
E-modulus
± 2 LSB
Mounting threads
M18×1.5 or 3/4"-16UNF
Ambient temp.
Humidity < 90 %, non-dewing
Protection rating per IEC 60529 with
connector attached:
cable version
[Hz]
(type tested at 5 bar / 48 h)
IP69/K with connected cable guard
1500
system
1000
8.2

Supply voltage (external)

666
Regulated supply voltage
500
BTL5-_1...
333
Ripple
Current draw
Inrush
Polarity reversal
protection
Overvoltage protection
Transzorb diodes
Electric strength
GND to housing
< 1 LSB
< 2 LSB
The CE Mark verifies
that our products meet 
the requirements of the current
EU Directive.
The BTL meets the
requirements of the following
product standard:
EN 61326-2-3
(noise immunity and emission)
8.3
Interface
< 5500 mm
Clock input:
➥ ➥ ➥ ➥ ➥ Fig. 3-1
(via optical coupler)
approx. 2 kg/m
Clock frequency
Stainless steel
Output data
1. 4404
Position
Stainless steel
information
1.4571
10.2 mm
2 mm
8.4
approx. 200 kN/mm
2
BTL5-...-FA05
with connecting cable,
axial arrangement, 5 m long
–40 °C to +75 °C
BTL5-...-F05
with connecting cable,
radial arrangement, 5 m long
IP 68
Teflon cable
The clock frequency is a function
of the cable length:
Cable length
< 25 m
20 to 28 V DC
< 50 m
< 0.5 V
pp
< 90 mA
< 100 m
< 3 A/0.5 ms
< 200 m
< 400 m
built-in
Table 8-1: Clock frequency
500 V DC
Emission tests:
RF Emission
Noise immunity tests:
Static electricity (ESD)
Electromagnetic fields (RFI)
Fast transients (Burst)
Surge
Line-induced noise induced by
high-frequency fields
Magnetic fields

Control signals

RS 485/422
+Clk, –Clk
max. 1000 kHz
+Data, –Data
24 or 25 bit
serial

Connection to processor

-40 °C to +200 °C
Clock frequency
< 1000 kHz
< 500 kHz
< 400 kHz
< 200 kHz
< 100 kHz
EN 55011
EN 61000-4-2
Severity level 3
EN 61000-4-3
Severity level 3
EN 61000-4-4
Severity level 3
EN 61000-4-5
Severity level 2
EN 61000-4-6
Severity level 3
EN 61000-4-8
Severity level 4
english
9

Publicité

Table des Matières
loading

Table des Matières