LED AC Wire speed.
Indicates that the display AL shows the wire speed in
welding.
LED AD Current.
Indicates that the display AL shows a welding current.
during welding always shows the measured current;
with the machine at a standstill, if Ag is oFF, shows
the set current.
LED Af - globular position.
may not be selected. Active in synergic mIg process.
When lit, this signals that the pair of values chosen for
welding may give unstable arcs and splatters.
LED Ag - Hold.
may not be selected. It signals that the values shown
on the displays AL and AM (normally Amperes and
volts) are those used during last welding. Activated at
the end of each welding session.
LED AH - Voltage.
In all welding processes, it indicates that the display
AM shows the re-set welding voltage or, if in combi-
nation with LEd Ag lit, the last measured voltage.
Knob AI.
The following values are set: welding current A, wire
speed (
), thickness (
the service functions the following are selected: TRg,
SP, HSA, CrA, Prf, Pof, Acc, bb, L, Dp, PPf, Ito, qc,
Utc, dst, fac.
In mIg synergic processes when a value is adjusted
the other values are adjusted as well. All these values
are shown on the display AL.
Knob AN.
The following sizes are set:
In synergic mIg the arc length, in conventional mIg
the welding voltage.
Inside the service menu, according to the value set by
knob AI it selects the set value, the activation or
desactivation of the same, or an additional selection
to be made inside the fuction.
Display AL.
In all welding processes, it numerically displays the
selections made via the selection key AE and adjust-
ed via the knob AI.
For the welding current (LEd AD) it displays the
amperes.
For the wire speed (LEd AC) it displays the meters per
minute.
For the thickness (LEd AB) it displays the millimeters.
For (LEd AA) it displays the set program number.
In the service functions the following are selected:
TRg, SP, HSA, CrA, Prf, Pof, Acc, bb, L, Dp, PPf,
Ito, fac.
For the parameters within the service functions that
are shown on the display AM, see the paragraph on
service functions.
When the machine is in the warning mode, it displays a
flashing warning (exemple: OPN if the lateral panel is
), program number PRg. In
open. When the machine is in the error mode it displays Err.
Display AM.
displays by the number: in synergic mIg the arc length
and in conventional mIg the welding voltage.
For the welding voltage (LEd AH) it displays the volts. For
the arc length (LEd AHoff) it displays a number between
9.9 and +9.9, 0 being the recommened value.
For the parameters in the mIg service function, that are
shown on the display AM, see the paragraph on service
functions .
When the machine is in error mode it displays the corre-
sponding error code between 1 and 99.
Selection key AO.
Each time this key is pressed, the selected process is
shown by LEd AP/AQ/AR.
LED AP Pulsed MIg.
shows that the selected process is the synergic mIg
pulsed.
LED AQ SYNERgIC MIg.
shows that the selected process is synergic mIg.
LED AR CONVENTIONAL MIg.
shows that the selected process is conventional mIg.
Selection key AU.
Each brief pressure selects 2 stages mode (mANUAL)
and the 4 stages mode (AUTomATIC), the selection is
shown on the display AL.
In the 2 stages mode the machine begins welding when
the welding torch trigger is pressed, and stops when
released.
In the 4 stages mode to begin welding press and release
the welding torch trigger; to interrupt, you must press and
release it again.
Selection key AV. (JOB)
saving and restoring of the stored processes.
To save a working condition (JOB), just hold down for at
least 3 seconds the key AV, the LEd AZ glows, on the
display AL the abbreviation STO flashes and on display
AM the number of the first available position flashes.
Knob AN is used to select the saving position; press
again key AV until a sound will confirm that it has been
saved and the selected number stops flashing.
To restore the saved number just briefly press key AV and
restore the number by means of knob AN. Up to 99 pairs
od current/voltage values may be saved.
To delete a saved number, press for at least 3 seconds
key AV, turn knob AI until the display ALshows the abbre-
viation DEL and press the key againAV for 3 more sec-
onds.
A current/voltage parameter may be restored outside
saving for both using or changing it. To restore it press
for 3 seconds key AV, display by menas of knob AI the
number to be restored and show on display AL, with
knobANthe abbreviation rcL; now just press for at least 3
seconds key AV.
LED AZ JOB.