Annexe B — Protocole RS-232 (suite)

2.6.3.13 Alarm Options Read Command

This command returns the current settings of the dispenser alarm options.
Client command and data: (STX) + 04 + EJ-- + CD + (ETX)
The above text packet in hexadecimal format:
STX
0
4
0x02
0x30
0x34
NOTE: "D0" is the letter "D" followed by the digit "0."
Return Format: D0INiIOoILlPOpPLbAEeAOa
A "1" indicates the alarm feature is enabled. A "0" indicates the alarm feature is disabled.
i:
Enable Input Alarm (IN)
o:
Enable Output Of Input Alarm (IO)
l:
Latch the Input Alarm (IL)
p:
Enable Output of the Pressure Alarm (PO)
b:
Latch the Pressure Alarm (PL)
e:
Enable Auto Increment Alarm (AE)
a:
Enable Output of the Auto Increment Alarm (AO)
EXAMPLE: If Enable Output of the Pressure Alarm (PO) and Latch the Pressure Alarm (PL) are enabled, the text
packet received from the dispenser is: (STX) + 17 + D0IN0IO0IL0PO1PL1AE0AO0 + BD + (ETX)
Length of the response text packet: Decimal 23 or hexadecimal 17
The above text packet in hexadecimal format:
STX
1
7
0x02
0x31
0x37
0
P
O
0x30
0x50
0x4F
B
D
ETX
0x42
0x44
0x03
www.nordsonefd.com/fr EFDEU-South@nordson.com
E
J
space space
0x45
0x4A
0x20
0x20
D
0
I
N
0x44
0x30
0x49
0x4E
1
P
L
1
0x31
0x50
0x4C
0x31
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
Doseur de Fluide Haute Précision Ultimus V
C
D
ETX
0x43
0x44
0x03
0
I
O
0
0x30
0x49
0x4F
0x30
A
E
0
A
0x41
0x45
0x30
0x41
I
L
0x49
0x4C
O
0
0x4F
0x30
73

Publicité

Table des Matières
loading

Table des Matières