Annexe B — Protocole RS-232 (suite)

2.6.3.3 Pressure Time Vacuum Read Command

This command returns the Dispense Pressure, Dispense Time, and Vacuum values of the specified address. This
command also update the LCD screen to the specified memory location.
Client command and data: E8ccc
ccc: The 3-digit memory location from 0–399. The dispenser will automatically limit value to prevent any errors.
EXAMPLE: To read the pressure, time, and vacuum values in memory location #1, the text packet is:
(STX) + 05 + E8001 + 8D + (ETX)
NOTE: This command changes the current memory location in the dispenser as set in the command (e.g., 001 in
above example command), in addition to returning the values for pressure, time, and vacuum.
The above text packet in hexadecimal format:
STX
0
5
0x02
0x30
0x35
NOTE: "D0" is the letter "D" followed by the digit "0."
Return Format: D0PDppppDTtttttVCvvvv
pppp: The 4-digit pressure setting excluding the decimal point. This is a unitless value. The valid pressure ranges
and decimal point are determined by the pressure units currently selected in the dispens
ttttt: The 5-digit dispense time value excluding the decimal point. The valid range is 0.0000 to 9.9999 seconds.
vvvv: The 4-digit vacuum setting excluding the decimal point. This is a unitless value. The valid vacuum ranges and
decimal point are determined by the vacuum units currently selected in the dispenser.
Interpreting the pressure setting from the return feedback value:
Value Received from the
Pressure Unit
Dispenser (pppp)
psi
0000–1000
kPa
0000–6895
Bar
0000–6895
Interpreting the vacuum setting from the return feedback value:
Value received from Ultimus
Vacuum Unit
V (vvvv)
H
O
0000–0180
2
kPa
0000–0448
Hg
0000–0132
mmHg or Torr
0000–0336
EXAMPLE: If the requested memory location is 1, the pressure setting at the memory location is 50.0 psi, the time
setting is 1.0055 s, and the vacuum setting is 10.0 H
(STX) + 15 + D0PD0500DT10055VC0100 + E0 + (ETX)
Length of the response text packet: Decimal 21 or hexadecimal 0x15
www.nordsonefd.com/fr EFDEU-South@nordson.com
E
8
0
0
0x45
0x38
0x30
0x30
O, the text packet received from the dispenser is:
2
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
Doseur de Fluide Haute Précision Ultimus V
1
8
D
0x31
0x38
0x44
0x03
Pressure Setting
0.0–100.0 psi
0.0–689.5 kPa
0.000–6.895 bar
Vacuum Setting
0.0–18.0 H
O
2
0.00–4.48 kPa
0.00–1.32 Hg
0.0–33.6 mmHg
ETX