Deposit Count Clear Command; Reset Auto Increment Command; Auto Increment Mode On / Off Command - Nordson EFD Ultimus V Manuel Utilisateur

Masquer les pouces Voir aussi pour Ultimus V:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Annexe B — Protocole RS-232 (suite)

2.6.2.15 Deposit Count Clear Command

This command resets the deposit counter on the dispenser to all zeros.
Client command and data: (STX) + 04 + EA-- + D6 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
0x02
0x30
0x34

2.6.2.16 Reset Auto Increment Command

This command resets the Auto Increment functions. The dispenser will set the Memory Address to the Start Address
Value, reset the counters, and clear the auto increment alarm. If the dispenser is not in counter or timer mode, the
dispenser returns a Failure Command (
Client command and data: (STX) + 04 + SE-- + C4 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
0x02
0x30
0x34

2.6.2.17 Auto Increment Mode On / Off Command

This command enables or disables the Auto Increment Mode. When enabling the Auto Increment Mode, the
dispenser will enable to Count Mode.
NOTE: This command is not necessary to enable Auto Increment Mode. The Auto Increment Mode command
(2.6.2.18) can be used instead.
Client command and data: AI--i
i:
Enable Command. 0=OFF, 1 = ON
EXAMPLE: To enable the Auto Increment Mode, the text packet is: (STX) + 05 + AI-- + 1 + A0 + (ETX)
The above text packet in hexadecimal format:
STX
0
5
0x02
0x30
0x35
www.nordsonefd.com/fr EFDEU-South@nordson.com
E
A
space space
0x45
0x41
0x20
0x20
A2
) text packet.
S
E
space space
0x53
0x45
0x20
0x20
A
I
space space
0x41
0x49
0x20
0x20
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
Doseur de Fluide Haute Précision Ultimus V
D
6
ETX
0x44
0x36
0x03
C
4
ETX
0x43
0x34
0x03
1
A
0
ETX
0x31
0x41
0x30
0x03
57