Annexe B — Protocole RS-232 (suite)

2.3.7 Text Packet Example

The following is a visual example of a text packet. This example uses the Pressure Set Command (
send a 50.0 psi value to the dispenser.
NOTE: The two hyphens (
The text packet:
Start of Text
No. Bytes
The text packet in hexadecimal format:
STX
0
8
0x02
0x30
0x38
Checksum calculation example based on the above text packet:
0 - 0x30 - 0x38 - 0x50 - 0x53 - 0x20 - 0x20 - 0x30 - 0x35 - 0x30 - 0x30
= 0xFDF0
The least significant byte of the above value is
The End of Text control character (
www.nordsonefd.com/fr EFDEU-South@nordson.com
--
) in the Pressure Set Command are used to denote two spaces (hex
Bytes Used for Checksum
Bytes Used for No. Bytes
Command
Data
Bytes used to calculate
the Checksum
P
S
space space
0x50
0x53
0x20
0x20
F0
, so this value is appended to the text packet after the Data bytes.
ETX
/
0x03
) is appended.
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
Doseur de Fluide Haute Précision Ultimus V
Checksum
End of Text
0
5
0
0
0x30
0x35
0x30
0x30
PS--0500
) to
0x20
).
Checksum
appended
F
0
ETX
0x46
0x30
0x03
45