Write Commands; Memory Change Command; Timed Mode Command; Steady Mode Command - Nordson EFD Ultimus V Manuel Utilisateur

Masquer les pouces Voir aussi pour Ultimus V:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Annexe B — Protocole RS-232 (suite)

2.6.2 Write Commands

These commands are sent by the client (PC / PLC) to the dispenser to change specific parameters or settings on the
dispenser. Write commands are sent using the sequence explained in "2.4.1 Write Text Packets" on page 46.
NOTE: The two hyphens (

2.6.2.1 Memory Change Command

This command changes the selected memory location of the dispenser. The LCD screen will update to the new
memory location, including updating the dispense time, pressure, and vacuum parameters.
Client command and data: CH--ccc
ccc: The 3-digit memory location from 0–399. The dispenser will automatically limit the value to prevent any errors.
EXAMPLE: To change the Memory Location to 001, the text packet is:
(STX) + 07 + CH-- + 001 + 3D + (ETX)
The above text packet in hexadecimal format:
STX
0
7
0x02
0x30
0x37

2.6.2.2 Timed Mode Command

This command switches the dispenser to the Timed mode.
Client command and data: (STX) + 04 + TT-- + B4 + (ETX)
The above text packet in hexadecimal format:
STX
0
4
0x02
0x30
0x34

2.6.2.3 Steady Mode Command

This command switches the dispenser to the Steady mode.
Client command and data: (STX) + 04 + MT-- + BB + (ETX)
The above text packet in hexadecimal format:
STX
0
4
0x02
0x30
0x34

2.6.2.4 Time / Steady Toggle Command

This command toggles the dispenser between Timed mode and Steady mode.
Client command and data: (STX) + 04 + TM-- + BB + (ETX)
The above text packet in hexadecimal format:
STX
0
4
0x02
0x30
0x34
www.nordsonefd.com/fr EFDEU-South@nordson.com
--
) shown in the commands represent ASCII space values (hex
C
H
Space Space
0x43
0x48
0x20
0x20
T
T
Space Space
0x54
0x54
0x20
0x20
M
T
Space Space
0x4D
0x54
0x20
0x20
T
M
Space Space
0x54
0x4D
0x20
0x20
+33 (0) 1 30 82 68 69 Les services et les points de vente des systèmes de dosage Nordson EFD sont présents dans le monde entier.
Doseur de Fluide Haute Précision Ultimus V
0
0
1
3
0x30
0x30
0x31
0x33
B
4
ETX
0x42
0x34
0x03
B
B
ETX
0x42
0x42
0x03
B
B
ETX
0x42
0x42
0x03
0x20
).
D
ETX
0x44
0x03
51

Publicité

Table des Matières
loading

Table des Matières