Annexe
A.4 Aperçu de la structure de commande HART
continuance
continuance
5 Config Inp/Outp
2 Input
3 Output
4 Local meter
to be continued
234
continuance
continuance
3 Meas Switch/Mapper
6 (measurement) config
e.g. Level
6 (measurement) config
e.g. Flow
6 (measurement) config
e.g. Customer
7 Unser linearization
if Level, Flow or Customer
this is valid - otherwise not
4 Meas.Limits & Span
1 Module range
2 Active Device Variables
additional if measurement
is mapped to level
additional if measurement
is mapped to level
additional if measurement
is mapped to level
additional if measurement
is mapped to flow
additional if measurement
is mapped to flow
additional if measurement
is mapped to customer
1 Analog output
1 Analog output
2 Percent range
3 Zero and Span
4 Pres xfer function
5 Startpoint square root
6 Current Limits
7 Alarms
2 Sensor trim points
1 Lower sensor trim point
2 Upper sensor trim point
3 HART output
1 Polling address
2 Num request preambles
3 Num response preambles
1 Meter type
2 Unit tracking
3 Local Display unit
3 Volume scaling
1 Volume unit
2 Vol LRV
3 Vol URV
2 Density unit
3 Density
3 Mass unit
1 Input scaling
1 Pres abs/rel
2 Pressure unit
3 Input LRV
4 Input URV
2 Flow scaling
1 Vol flow unit
2 Vol flow LRV
3 Vol flow URV
2 Density unit
3 Density
3 Mass flow unit
1 Input scaling
1 Pres abs/rel
2 Pressure unit
3 Input LRV
4 Input URV
3 Customer scaling
1 Cust unit (5 Ch)
2 Cust LRV
3 Cust URV
1 Special Curve status
-->
only if meas not pres
2 No curve points
3 Setup special char --> M
4 Display special char --> M
1 Pressure
1 Pressure unit
2 Pres USL
3 Pres LSL
4 Trimpoint sum
5 Pres min.span
2 Sens-Temp
1 Sens-Temp unit
2 Sens-Temp USL
3 Sens-Temp LSL
4 Sens-Temp min.span
3 Electr-Temp
1 Electr-Temp unit
2 Electr-Temp USL
3 Electr-Temp LSL
4 Electr-Temp min.span
4 Untrimmed Pres
1 Untrimmed Pres unit
2 Untrimmed Pres USL
3 Untrimmed Pres LSL
4 Untr Pres min.span
5 Level
1 Level unit
2 Level USL
3 Level LSL
4 Level min.span
6 Volume
1 Volume unit
2 Volume USL
3 Volume LSL
4 Volume min.span
7 Mass
1 Mass unit
2 Mass USL
3 Mass LSL
4 Mass min.span
5 Vol-Flow
1 Vol-Flow unit
2 Vol-Flow USL
3 Vol-Flow LSL
4 Vol-Flow min.span
6 Mass-Flow
1 Mass-Flow unit
2 Mass-Flow USL
3 Mass-Flow LSL
4 Mass-Flow min.span
5 Customer
1 (PV) unit
2 Customer USL
3 Customer LSL
4 Customer min. span
1 Zero/Span set
1 Apply values >1
2 Out Scaling PV
>1 Out Scaling PV
1 Unit
2 LRV
3 URV
4 LSL
5 USL
>2 Apply values
1 Apply values --> M
1 Lower AO Limit
2 Upper AO Limit
1 AO Alarm Type
2 Alarm LRV
3 Alarm URV
SITRANS P, série DS III avec HART
Instructions de service, 08/2011, A5E00053218-07