Programmation
6.3.7 5-** E/S Digitale
Description du paramètre
par. #
5-0* Mode E/S digitales
5-00
Mode E/S digital
5-01
Mode born.27
5-02
Mode born.29
5-1* Entrées digitales
5-10
E.digit.born.18
5-11
E.digit.born.19
5-12
E.digit.born.27
5-13
E.digit.born.29
5-14
E.digit.born.32
5-15
E.digit.born.33
6
6
5-16
E.digit.born. X30/2
5-17
E.digit.born. X30/3
5-18
E.digit.born. X30/4
5-19
Arrêt de sécurité borne 37
5-20
E.digit.born. X46/1
5-21
E.digit.born. X46/3
5-22
E.digit.born. X46/5
5-23
E.digit.born. X46/7
5-24
E.digit.born. X46/9
5-25
E.digit.born. X46/11
5-26
E.digit.born. X46/13
5-3* Sorties digitales
5-30
S.digit.born.27
5-31
S.digit.born.29
5-32
S.digit.born. X30/6
5-33
S.digit.born. X30/7
5-4* Relais
5-40
Fonction relais
5-41
Relais, retard ON
5-42
Relais, retard OFF
5-5* Entrée impulsions
5-50
F.bas born.29
5-51
F.haute born.29
5-52
Val.ret./Réf.bas.born.29
5-53
Val.ret./Réf.haut.born.29
5-54
Tps filtre pulses/29
5-55
F.bas born.33
5-56
F.haute born.33
5-57
Val.ret./Réf.bas.born.33
5-58
Val.ret./Réf.haut.born.33
5-59
Tps filtre pulses/33
5-6* Sortie impulsions
5-60
Fréq.puls./S.born.27
5-62
Fréq. max. sortie impulsions 27
5-63
Fréq.puls./S.born.29
5-65
Fréq. max. sortie impulsions 29
5-66
Fréq.puls./S.born.X30/6
5-68
Fréq. max. sortie impulsions X30/6
5-7* Entrée cod. 24V
5-70
Pts/tr cod.born.32 33
5-71
Sens cod.born.32 33
5-8* Sortie codeur
5-80
AHF Cap Reconnect Delay
5-9* Contrôle par bus
5-90
Ctrl bus sortie dig.&relais
5-93
Ctrl par bus sortie impulsions 27
5-94
Tempo. prédéfinie sortie impulsions 27
5-95
Ctrl par bus sortie impulsions 29
5-96
Tempo. prédéfinie sortie impulsions 29
86
Manuel d'utilisation
Valeur par défaut
[0] PNP
[0] Entrée
[0] Entrée
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
0.01 s
0.01 s
100 Hz
100 Hz
0 ReferenceFeedbackUnit
ExpressionLimit
100 ms
100 Hz
100 Hz
0 ReferenceFeedbackUnit
ExpressionLimit
100 ms
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
1024 N/A
[0] Sens horaire
25 s
0 N/A
0 %
0 %
0 %
0 %
Danfoss A/S © Rév. 2014-02-07 Tous droits réservés.
4 process
Changement
pendant le
conversion
fonction-
nement
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
1 set-up
TRUE
Indice de
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
0
Uint32
-
Uint8
0
Uint32
-
Uint8
0
Uint32
0
Uint16
-
Uint8
0
Uint16
0
Uint32
-2
N2
-2
Uint16
-2
N2
-2
Uint16
MG37A204