Installing Indoor Unit - Haier AC092ACBHA Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation of Indoor Unit
3. INSTALLING BRACKETS
Install the brackets with nuts, washers and spring washers.(Fig. 14)
(Fig. 14)
Spring washer
Special nut

4. INSTALLING INDOOR UNIT

Reset the hex bolts as shown in Fig.15.
(Fig. 15)
Indoor unit
Apply the indoor unit to the brackets.(Fig.16)
5. INSTALL THE DRAIN HOSE
Select whether the drain hose will be connected to the left or right side.(Fig.3)
Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener.(Fig.6)
Wrap the insulation (drain hose)around the drain hose connection.(Fig.7)
Be sure to arrange the drain hose correctly so that it is leveled lower than the drain hose connecting port of the
indoor unit.(Fig.8)
All manuals and user guides at all-guides.com
68 16 21 28
Bracket
26.5
232
Hex bolt
8 to 13mm
(Fig. 16)
Now, securely tighten the hex bolts in both sides.
Bracket (Left)
For series 14,18,24
381
26.5
2-R2.5
2-R2.5
26.5
381
For series 28,36,42
Bolt
Indoor unit
17
Bracket (Right)
232
26.5
68
28
21
16
Bracket

Publicité