Connection Pipe Requirement; Installation Procedure - Haier AC092ACBHA Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation of Indoor Unit

CONNECTION PIPE REQUIREMENT

Table 1
M o d e l
AC142ACBEA
AC182ACBEA
AC242ACBEA AC28NACBEA
AC36NACBEA AC42NACBEA

INSTALLATION PROCEDURE

Install the room air conditioner as follows:
PREPARING INDOOR UNIT INSTALLATION
1. REMOVE THE INTAKE GRILL
Open the intake grill and remove the
three or four or six screws.(Fig. 1)
Remark: The main unit can be wired before
the indoor unit is installed. Select
the most appropriate installation
order.
A. FLOOR CONSOLE TYPE
(For series 36,42 no this type )
1. DRILLING FOR PIPING
Select piping and drain directions.(Fig.2) (Series14,18,24)
The piping and drain can be made in three directions as shown below.
For series 28,36,42 can be made rear and down two directions.
(Fig. 2)
The drain hose can be connected to either the left or right side.(Fig.3) For series 28,36,42.only right side.
(Fig.3)
Drain hose (Left side)
All manuals and user guides at all-guides.com
Diameter
Liquid side
Gas side
6.35 mm
12.7 mm
6.35 mm
15.88 mm
9.52 mm
15.88 mm
9.52 mm
19.05mm
(Fig. 1)
Tapping screw
Intake grill
rear
right
down
When the directions are selected, drill a 7 cm dia. hole on the wall so
that the hole is tilted downward toward the outdoor for smooth water
flow. When the pipe is led out from the rear, make a hole in Fig.6, at
the position shown.
Drain hose (Right side)
Maximum height
Maximum
(between indoor
length
and outdoor)
30 m
30 m
20 m
30 m
50 m
30 m
Machine screw
Tapping screw
For series 28,36,42, have not the power plug.
14
20 m
20 m

Publicité

Table des Matières
loading

Table des Matières