Personalization Of Working Parameters; Safety Devices - Dea 400RR Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
5 Channel selection and linking on the transmitter
The built-in receiver can control both the start input and the pedestrian one. By setting the correct value of the parameter "P009 Se-
lection and linking of radio channels" it is possible to decide which button of the transmitter will activate each input. If you check on the
"working parameters" table you will realize that the P009 parameter allows you to choose among 16 different combinations. If, for instance,
you attribute value "3" to the parameter P009, all memorized transmitters will activate the start input through the CH1 and the pedestrian
input through CH4. Please see chapter "8.4 Personalization of working parameters" in order to select the right combination.

5.1 Personalization of working parameters

Instructions
1. The control board is ready to receive instructions
2. Scroll down the parameters until you visualize the one you wish to set (ex. P010)
3. Confirm! The display shows the set parameter value
4. Increase or decrease the value until you reach the value you wish to define
5. Confirm! The display shows again the parameter
6. Scroll down the parameters until you visualise "- - - -". The control board awaits further instructions
7. The operator is now ready to work according to the new working parameters.
5.2 Resetting of default parameters (P007)
400RR control board software includes a reset procedure to restore default values (the one set by the maker) of all settable parame-
ters, see Table 2 Parameters. The value originally set for each parameter is shown in the "working parameters table". In case you should
reset all values and restore all default values, proceed as follows:
Instructions
1. The control board is ready to receive instructions
2. Scroll down the parameters until you visualize P007
3. Confirm! The control board awaits a further confirmation
4. Confirm by pressing on the OK button. The procedure starts
5. All parameters are now set at their original value
6. Scroll down the parameters until you visualise "- - - -". The control board awaits further instructions

5.3 Safety devices

The control board 400RR allows installers to set up installations truly comply with European regulations concerning automatic enclosu-
re devices. More specifically, this control board allows you to comply with the limits set by the same regulations as to impact forces in case
of collision with obstacles.
400RR control board in fact, when used with DEA operators equipped with encoder (parameter P034=0) has a built-in anti-crush safety
device, that, associated to the possibility of adjusting the motor speed, allows you to comply with the limits imposed by the above mentio-
ned regulations in most installations. In particular you can adjust the anti-crush safety device sensitivity by the proper adjustment of the
values assigned to the following parameters:
• P014 motor force in opening cycle: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity);
• P015 motor force in closing cycle: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity);
WARNING in case of operators without encoder (P034=1) the speed adjustment and the anti-crush device are not activated.
In case the gate structural features do not allow you to comply with the above force limits, it is possible to use external safety device
inputs (clamp n°12). "CST" input can be configured by setting properly parameter P018:
• P018=0
"safety edge" mode functioning: when the input is activated, it reverses the movement direction;
• P018=1
"photoelectric barrier" mode functioning: when the input is activated, it stops the movement
WARNING If the CST input is not used, shortcircuit it to terminal n°16 or n°24. If you power the external safety devices by using 24VSIC
output (terminal n°12), their proper working is tested before each gate operation.