Timer
Operating time can be set from 0.5 to 7.5 hours by pressing the TIMER button 1 to
5 times. The time set is displayed on the screen. At the end of the period set, the
air-conditioner will automatically switch off (Fig. 7-11).
Automatic drainage of condensed water
As soon as the condensed water in the collection tray in the indoor unit reaches a
certain level (0.8 litres), the pump will automatically discharge the water to the
condenser in the outdoor unit. In the outdoor unit, the water partially evaporates
together with the discharge of warm air. The remaining water is discharged through
a drainpipe at the underside of the outdoor unit.
In case of interruption, you will hear a buzzer (alarm) for 20 seconds and the
appliance will switch off. By removing the plug from the bottom side of the indoor
unit, the water can be drained and subsequently you can use the appliance again.
Whenever you want to move the indoor unit, it is wise to first drain the water from
the indoor unit by removing one of the sealing plugs. Otherwise, you run the risk
that water leaks into the indoor unit while moving the appliance.