Display the required value
press the
press the
value.
Modify the required value (required temperature)
to modify the required value, press
the display will show the required value, and the LED
with
or
required value on the display;
save the new value with
NOTE!
To modify parameters or other settings, follow the instructions on how to control
the temperature or call the service to introduce the required modification.
Defrost
Automatic defrost
In 24 hours the device defrosts 4 times automatically. The time counting starts at the initial
start up of the device.
In the case you need to modify the defrost time set, press and hold the
longer than 5 seconds. The display shows the "
The defrost starts immediately, and it will repeat in 6 hours.
Manual defrost
Despite the automatic defrost cycle, you can initiate the manual defrost at any time by
pressing and holding the
and the display shows "
NOTE!
The defrost water is drained to the bottom of the device and evaporates.
- 36 -
button briefly to display the required value;
button again or wait for 5 seconds to return to the previous display
you can decrease or increase the value until you see the
or wait 10 seconds to save the set value automatically.
button for longer than 5 seconds. The manual defrost starts
".
and hold for longer than 2 seconds;
or
" symbol.
will flash on the display;