Programmable Functions - Nice MhouseKit WU200S Instructions Et Avertissements Pour L'installation Et L'utilisation

Kit complet pour automatiser un portail battant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CL200S command control unit
Type
Technology adopted
Maximum cycles frequency
Maximum continuous cycle time
Mains power supply
Nominal absorbed power
Emergency power supply
Motors output
FLASH output
ECSBus output
"OPEN" input
"STOP" input
Radio Antenna input
Maximum cable length
Ambient operating temperature
Use in acid, saline or potentially explo-
sive atmospheres
Mounting
Protection rating
Dimensions / weight
Remote control compatibility
Memorisable GTX4 transmitters
Range of the GTX4 transmitters
Programmable functions
Self-programming functions
30 – English
Command control unit for 1 or 2 24Vdc motors for automation of automatic gates or doors,
complete with radio receiver for "GTX4" transmitters
Electronic board governed by an 8 Bit microcontroller with flash technology
A transformer inside the control unit, but separated from the board, reduces the mains volt-
age to the nominal 24V voltage used in all of the automation system
15 cycles/hour at 50°C
5 minutes
230Vac (+10% -10%) 50/60Hz.
170W; at peak the power is 360W for a maximum duration of 2s
Provision for "PR1" buffer battery connection
2, for 24Vdc motors with a nominal current of 2A, at peak power the maximum current is 5
A for a maximum duration of 2 s
For traffic lights: flashing light indicator lamp of 12 V maximum 21 W, Courtesy light lamp
24 V maximum 4 W, Gate open indicator lamp 24 V maximum 4 W.
One output with maximum load of 15 ECSBus units
For normally open contacts (the closing of the contact causes the "Open or Pedestrian
Opening" command)
For normally closed or normally open contacts and/or for constant resistance of 8.2 KΩ, or
normally closed contacts with self-recognition of the "normal" state (any variation from the
memorised status causes the "STOP" command).
50 Ω for RG58 or similar type of cable
Mains power supply: 30m; motors outputs: 10m; other inputs/outputs: 20m with antenna
cable preferably shorter than 5m (observe the warnings regarding minimum gauge and
type of cables)
-20 ÷ 50°C
No
Vertical, wall-mounted
IP44
180 x 240 h 110mm / 2.8kg
Using "GTX4" transmitters, the control unit is able to receive one or more of the following
commands: "OPEN", "Partial Open", "Open Only" and "Close Only"
Up to 150 if memorised in mode 1
From 50 to 100m. This range can vary if there are obstacles or electromagnetic distur-
bances, and is affected by the position of the receiving aerial incorporated in the flasher
"Cycle" or "Complete cycle" (automatic closure) functionality
"Slow" or "fast" motors speed
Pause time during "complete cycle", selectable from 10, 20, 40, 80 seconds
Partial opening type selectable in 4 modes
Obstacle detection system sensitivity, 4 selectable levels
Obstacle detection system sensitivity, 4 selectable levels
"OPEN" command functionality selectable in 4 modes
Open input configuration on the control unit: open or pedestrian opening
FLASH output configuration: flashing light, courtesy light or gate open indicator
Motors discharge on closure selectable from 8 levels
Motors discharge on opening selectable from 8 levels
Self-recognition of devices connected to the ECSBus output
Recognition of the type of "STOP" device (NO or NC contact or 8.2 KΩ constant resistance)
Recognition of the manoeuvre length for each motor
Automation recognition with 1 or 2 motors