Determine an appropriate mounting location inside the light fixture
minimizing the electric light contribution to the sensor's photocell. Allow
a minimum distance of 0.2" (5.1mm) from the wiring end of the sensor
to the wall of the fixture.
There are two mounting methods for the FSP-202D—using the
threaded collar or using the snap-in tabs.
Threaded Collar Mounting
1. Drill a hole 1.30" (33.0mm) in diameter through the sheet metal in
the bottom of the fixture.
NOTE: The Outside Fixture Wall thickness should be no greater
than 0.125" (3.18mm) for optimal sensor mounting and
security.
2. Add the rubber gasket to the threaded collar, and install the sensor
face down, parallel to the mounting surface. Ensure the rubber
gasket touches the inside surface of the fixture. Install the plastic
nut (or optional collar) securely against the fixture to a torque of
25–30 in-lbs to ensure IP rating is maintained.
3. Align the locking features between the sensor and lens module
assembly and push the lens module forward until the o-ring seals
firmly. Turn the lens module clockwise to ensure it locks in place.
4. Connect wires as shown in wiring diagram.
5. Restore power from the circuit breaker.
NOTE: An optional collar can be installed in place of the tightening nut.
See the Ordering Information table on page 6 for details.
Snap-In Mounting
1. Cut a rectangular hole 55.6mm (± 0.2mm) by 33.5mm (± 0.2mm)
through the sheet metal in the bottom of the fixture. The bottom of
the fixture must be between .75mm and 3.2mm thick.
2. Push the FSP-202D up from below the fixture until the tabs "snap"
and the fixture locks in place.
3. Align the locking features between the sensor and lens module
and push the lens module assembly forward until the o-ring seals
firmly. Turn the lens module clockwise to ensure it locks in place.
4. Connect wires as shown in wiring diagram.
5. Restore power from the circuit breaker.
NOTE: When using snap-in mounting, the FSP-202D is not rated for
IP66.
OUTDOORS—USE AT THE EXPOSED SENSOR COLLAR PART ONLY WHEN INSTALLED AT THE SPECIFIC
LOCATION PER INSTALLATION INSTRUCTIONS WITH A LISTED OUTDOOR ENCLOSURE.
INSTALLATION
TURN THE POWER OFF AT THE CIRCUIT BREAKER
Inside Fixture
Wall
Tightening Nut
(or Optional Collar)
Inside Fixture
Wall
2
WARNING
BEFORE INSTALLING THE SENSOR.
FSP-202D
Rubber
Gasket
Outside
Tightening Nut
Fixture Wall
(or Optional Collar)
Threaded Collar Mounting
55.6mm (± 0.2mm)
Fixture Bottom
Cutout for snap-in mounting
Outside
Fixture Wall
FSP-202D
Snap-in Mounting
Rubber
Fixture
Gasket
Wall
Lens Assembly
Fixture
Wall
Lens Assembly