DESCRIPTION AND OPERATION
The FSP-212D is a motion sensor that dims lighting from high to
low based on movement. This slim, low-profile sensor is designed
for installation inside the bottom of a light fixture with a 0-10V output
dimmable ballast or LED driver control.
The sensors use passive infrared (PIR) sensing technology that reacts to
changes in infrared energy (moving body heat) within the coverage area.
Once the sensor stops detecting movement and the time delay elapses
lights will go from high to low mode and eventually to an OFF position if
it is desired. Sensors must directly "see" motion of a person or moving
object to detect them, so careful consideration must be given to sensor
luminaire placement and lens selection. Avoid placing the sensor where
obstructions may block the sensor's line of sight.
The FSP-212D has a photocell to read the light level and can
continuously raise or lower the dimming level of the lighting loads, based
on the ambient light and the desired light level setting.
The FSP-212D operates at 120V/230V-240V Single Phase/277V.
It is designed to be installed in indoor and outdoor environments,
and provides easy to use selectable modes with several adjustable
parameters.
The FSP-212D offers four different control modes of operation, (plus
service and test modes) that can be selected using a rotary pot. Once
powered up, each mode has a factory default set of parameters.
Additionally, sensor adjustment is available for time delay and high/low
dim levels via rotary pots.
NOTE: The FSP-212D is not compatible with non-isolated LED drivers.
Several lenses are available for use with the FSP-212D. Lenses give coverage at mounting heights between 8' - 40' for applications
such as, offices, warehouses and outdoor use. Density and range of the coverage is determined by the type of lens and mounting
height. A lens with shroud option is also available. The shroud blocks light coming from the fixture, to prevent interference with the
photocell function of the sensor. Lens modules are IP66 rated when combined with an FSP-212D sensor mounted to an outdoor rated
fixture. See the FSP-Lx Coverage Guide for more information.
Wattstopper
Selectable Mode Continuous Dimming Line Voltage PIR Fixture Integrated Sensor
Détecteur pour intégration au luminaire à gradation continuelle er mode
sélectionable de tension de ligne
Sensor PIR de Voltaje de Línea con atenuación continua para luminarias y
Modo Seleccionable
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
Voltage .................................................. 120V/277V, 50/60Hz
Load Ratings
Class 1 Wiring ........................ 18AWG, Length 36" (91.44cm)
Operating Temperature ........... -40°F (-40°C) to 158°F (70°C)
Tightening Nut Torque .......................................... 25-30 in-lbs
Dimensions
Weight .............................................................5.29 oz (150 g)
Enclosure ...................................................IP66 (NEMA STD)
Coverage
* Not compatible with non-isolated LED drivers
Sensor Protection Cap
NOTE: Remove Cap before use
LENS OPTIONS
®
SPECIFICATIONS
................................. 230–240V, 50/60Hz, Single Phase
@ 230-240V .................. 0–300W Ballast or LED Driver*
@ 120V .......0–800W Tungsten, Ballasts or LED Driver*
@ 277V ....................... 0–1200W Ballast or LED Driver*
Motor @ 120V/277V............................................. 1/6 HP
Line Voltage ......................................Line, Neutral, Load
Low Voltage (Class 1) .........Dim + (purple), Dim – (pink)
Collar ....................................... 1.87" diameter (47.5mm)
Collar height ........................................... 0.64" (16.3mm)
Body .. 2.5"L x 1.5"W x .83"H (63.3mm x 38mm x 21.1mm)
FSP-L2 Lens @ 8' height ................... up to 44' diameter
FSP-L3 Lens @ 20' height ................. up to 40' diameter
FSP-L7 Lens @ 40' height ............... up to 100' diameter
Dimming/
Hold Off
Setpoint/
High Trim
10V
Adjust
Mode
Selection
PIR Sensor
Motion Indicator
Red LED
1V
Time
Delay
Light Sensor

Publicité

Table des Matières
loading

Sommaire des Matières pour LEGRAND Wattstopper FSP-212D

  • Page 1 Wattstopper ® Selectable Mode Continuous Dimming Line Voltage PIR Fixture Integrated Sensor Détecteur pour intégration au luminaire à gradation continuelle er mode sélectionable de tension de ligne No: 27547 – 11/21 rev. 6 Sensor PIR de Voltaje de Línea con atenuación continua para luminarias y Modo Seleccionable Installation Instructions •...
  • Page 2 INSTALLATION Determine an appropriate mounting location inside the light fixture WARNING minimizing the electric light contribution to the sensor’s photocell. TURN THE POWER OFF AT THE CIRCUIT BREAKER Allow a minimum distance of 0.2” (5.1mm) from the wiring end of the BEFORE INSTALLING THE SENSOR.
  • Page 3: Control Modes

    CONTROL MODES The FSP-212D has five selectable modes, each of which has preset parameter settings. Once the mode is selected, you have the ability to further customize operation by adjusting the Set and the Time rotary trimpots. Select the Mode and adjust the other rotary trimpots using a small screwdriver. NOTE: A sixth mode, Test mode, is accessed automatically when mode A is selected.
  • Page 4 Mode B – Continuous Dimming Control with Daylighting (Dim to Off ) Features: Adjustable photocell level to set desired light level when occupied Mode B When the ambient lighting is below the desired light level and occupancy is Target Level Daylight detected, the sensor turns the loads ON.
  • Page 5 Mode E – Service/Setup Mode Mode E Features: Allows visual adjustment of High Trim level Applies Day or Night If the Time trimpot is set at maximum, the load turns ON at the current High Trim amount. Time Delay Time Delay set to maximum set to minimum Adjust the Set trimpot to the desired amount.
  • Page 6: Ordering Information

    Lights will not turn OFF: • Make sure the FSP-212D is not set to Mode E (Service mode) and time delay rotary trimpot is not at max position. • To quickly test the unit operation, enable test mode and move out of the sensor’s view. Lights should fade to the dim level after 5 seconds and then turn OFF after 2.5 seconds.
  • Page 7: Description Et Fonctionnement

    INSTRUCTIONS EN FRANÇAIS DESCRIPTION ET FONCTIONNEMENT SPÉCIFICATIONS Le FSP-212D est un détecteur de mouvements qui réduit Tension ..............120V/277V, 50/60Hz l'éclairage selon le mouvement. Ce détecteur mince et discret est ............230–240V, 50/60Hz, monophasé conçu pour être installé à l'intérieur d'un luminaire, dans le bas, Capacité...
  • Page 8 2. Ajoutez le joint en caoutchouc au collier fileté et installez le détecteur face vers le bas, parallèle à la surface d’installation. Assurez-vous que le joint en caoutchouc touche la surface intérieure du luminaire. Installez l’écrou en plastique (ou col optionnel) fermement contre le luminaire à...
  • Page 9: Modes De Régulation

    MODES DE RÉGULATION Le FSP-212D possède cinq modes sélectionnables, chacun ayant des paramètres de réglage prédéfinis. Une fois le mode sélectionné, vous pouvez personnaliser davantage le fonctionnement en réglant les potentiomètres de gradation et de temps. Sélectionnez le Mode et réglez les autres potentiomètres rotatifs à l’aide d’un petit tournevis. REMARQUE: Un sixième mode, le mode de test, est accessible automatiquement lorsque le mode A est sélectionné.
  • Page 10 REMARQUE: Lorsque vous sélectionnez le mode A, le dispositif FSP-212 entrera initialement en mode test et y restera pendant 5 minutes, après quoi il passera au fonctionnement en mode A. (Le mode test est identique au mode A, à l’exception de la temporisation qui est réglée à...
  • Page 11: Mode Test

    Mode D – Contrôle de gradation continue avec lumière ambiante (niveaux distincts de gradation faible lorsque la zone est inoccupée) Caractéristiques : Niveau de cellule photoélectrique réglable au Mode D Niveau cible Lumière du jour Luminosité niveau de luminosité désiré; un niveau de luminosité minimal est désirée toujours maintenu, selon les niveaux distincts configurés pour le jour et la nuit...
  • Page 12: Dépannage

    Résumé du mode Régulation de la Gradation élevée/faible Temporisation Marche automatique Arrêt automatique lumière du jour Mode A Réglage élevé/ 30 sec à 30 min Présence détectée La moitié de la 10 % du réglage élevé temporisation est expirée 1/2 des valeurs réglées pendant le réglage faible Mode B*...
  • Page 13: Renseignements Pour Commandes

    RENSEIGNEMENTS POUR COMMANDES Numéro de Description Catalogue FSP-212D Détecteur pour intégration au liminaire à gradation continuelle er mode sélectionable FSP-L2 Lentille 360°, jusqu'à 44 pi de diamètre à 8 pi de hauteur FSP-L3 Lentille 360°, jusqu'à 40 pi de diamètre à 20 pi de hauteur FSP-L7 Lentille 360°, jusqu'à...
  • Page 14: Descripción Y Funcionamiento

    INSTRUCCIONES EN ESPAÑOL DESCRIPCIÓN Y FUNCIONAMIENTO ESPECIFICACIONES El FSP-212D es un sensor de movimiento que atenúa la Voltaje ..............120V/277V, 50/60Hz iluminación de mayor a menor en función de movimiento. Este ............230–240V, 50/60Hz, fase simple sensor delgado y de bajo perfil está diseñado para su instalación Especificaciones de carga dentro de la parte inferior de una lámpara con un balasto @ 230–240V ....
  • Page 15 2. Agregue el empaque de goma al collarín roscado e instale el sensor boca abajo, paralelo a la superficie de montaje. Asegúrese de que el empaque de goma toque la superficie interior de la luminaria. Instale la tuerca plástica (o collarín opcional) firmemente contra la luminaria con un par de 25 a 30 in-lb para garantizar que se mantenga la clasificación IP.
  • Page 16 MODOS DE CONTROL El FSP-212D tiene cinco modos seleccionables, cada uno de los cuales tiene ajustes de Regulación parámetros preestablecidos. Una vez que se selecciona el modo, tienes la capacidad de personalizar aún más la operación ajustando los potenciómetros rotativos de Set y Time (Ajuste y Tiempo).
  • Page 17 NOTA: Cuando selecciones el modo A, el FSP-212D ingresará inicialmente al modo de Prueba y permanecerá en modo de prueba durante 5 minutos, luego de lo cual pasará a la operación del modo A. (El Modo de Prueba es idéntico al modo A, con la excepción del Tiempo de Retardo, que se fija a 5 segundos).
  • Page 18: Modo De Prueba

    Durante la noche, cuando se detecta ocupación, el nivel de atenuación se ajusta al nivel de luz deseado. Cuando no hay ocupación y el tiempo de retardo expira, el nivel de carga se atenuará al nivel de Atenuación Baja Nocturna (40% del valor de Ajuste Alto) para mantener un nivel de luz seguro.
  • Page 19: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS Las luces no se encienden a su valor máximo: • Asegúrese de que el sensor no esté bloqueado. • Si el modo se establece en A o B, compruebe el parámetro de nivel de luz para conocer la cantidad de luz que el sensor está detectando.