No: 24000 – 11/17 rev. 2
Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: DW-100/DW-100-347/DW-200
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
DW 100
The DW Dual Technology Wall Switch sensors combine advanced passive infrared (PIR) and ultrasonic technologies into one unit. The
combined technologies help to eliminate false triggering even in difficult applications.
Selectable operating modes allow the sensor to turn a load ON, and hold it ON as long as either or both technologies detect occupancy.
After no movement is detected for the selected time delay, the lights switch OFF. A "walk-through" mode can turn lights off after only 3
minutes, if no activity is detected after 30 seconds following an occupancy detection.
The DW-100 has one relay and one ON/OFF button. The DW-200 contains two relays and two ON/OFF buttons to allow control of one
or two loads independently. Pressing a button toggles the state of the corresponding relay.
DW sensors contain a light level sensor. If adequate daylight is present, the sensor holds the load OFF until light levels drop, even if the
area is occupied. In the DW-200, light level only affects the load on Relay 2. Users can overrule this function by pressing the ON/OFF
button. See Light Level Adjustment.
Turning ON the Load (ON Mode)
The relays are programmed independently for either Auto ON or Manual ON. In either mode, the load can be turned ON or OFF using
the ON/OFF button.
Manual ON
DIP 8 ON for Relay 1
DIP 9 ON for Relay 2
Auto ON
DIP 8 OFF for Relay 1
DIP 9 OFF for Relay 2
Model #
DW-100
DW-100-347
DW-100-347
DESCRIPTION AND OPERATION
With an ON Mode DIP switch in the ON position, the occupant must press the ON/OFF button to turn
ON the load. The sensor keeps the load ON until no motion is detected for the selected time delay.
There is a 30 second re-trigger delay. If occupancy re-triggers during the delay (see Trigger Mode), the
sensor turns the load back ON. After the re-trigger delay elapses the ON/OFF button must be pressed to
turn ON the load.
With an ON Mode DIP switch in the OFF position, the load turns ON and OFF automatically based on
occupancy. If the load is turned OFF manually, Presentation Mode operation applies. This prevents
the load from turning ON automatically after it was deliberately turned OFF. Pressing the button to turn
lights ON returns the sensor to Auto ON mode.
Relay
Default ON Mode
1
Manual ON
1
Manual ON
Wattstopper
Dual Technology Wall Switch Occupancy Sensors (version 3)
Interrupteur mural avec détecteurs de mouvement à technologie double (v3)
Sensores de ocupación e interruptor de pared con tecnología doble (v3)
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
Voltages:
DW-100 & DW-200................................ 120/277VAC, 50/60Hz
DW-100-347 ................................................. 347VAC, 50/60Hz
Load Limits for each relay:
@120VAC .........................0-800W tungsten or ballast, 1/6 HP
@277VAC .......................................................0-1200W ballast
@347VAC .......................................................0-1500W ballast
Load Type Compatibility:
Incandescent, fluorescent, magnetic or electronic ballast
Horsepower Rating (each relay) .................. 1/6 HP @120VAC
Time Delay Adjustment ............................................ 5 to 30 minutes
Walk-Through Mode ........... 3 minutes if no activity after 30 sec.
Test Mode .................. 5 sec. for 10 min. with DIP switch setting
PIR Adjustment ............................................ High or Low (DIP switch)
DW-200
Ultrasonic Adjustment ................. Minimum to Maximum (trimpot), Off
Frequency ..........................................................................40kHz
Light Level Adjustment ................................................. 8fc to 180+fc
Alerts ................................................................... Selectable Audible
US Patents: 5640113, 6617560
DIP Switch #
8
8
®
SPECIFICATIONS
Setting
ON
ON
Table des Matières
loading

Sommaire des Matières pour LEGRAND Wattstopper DW-100

  • Page 6: Description Et Fonctionnement

    INSTRUCTIONS EN FRANÇAIS DESCRIPTION ET FONCTIONNEMENT SPÉCIFICATIONS Les détecteurs interrupteurs muraux à double technologie DW allient Tensions : les technologies de l’infrarouge passif (IRP) et des ultrasons en une DW-100 et DW-200 ......120/277 V CA, 50/60 Hz seule unité. Les technologies combinées permettent d’éliminer les faux DW-100-347 ..........
  • Page 7: Mode Passage

    Test/20 min Le mode test, avec une temporisation courte de 5 secondes, est lancé lorsque les interrupteurs DIP 1 et 2 sont DÉSACTIVÉS. Il s'arrête automatiquement au bout de 10 minutes ou lorsque vous définissez (DIP 1 et 2 DÉSACTIVÉS) un délai de temporisation fixe.
  • Page 8: Détecteur Irp

    PORTÉE Vue du dessus un test relatif à la portée a été effectué conformément aux instructions NEMA WD 7. Pour de meilleures performances, ne l'utilisez pas dans des endroits plus grands Mouvement majeur Mouvement majeur que 5,5 m x 4,6 m (18 pi. x 15 pi.). Mouvement mineur Mouvement mineur Couverture...
  • Page 9: Réglages De L'interrupteur Dip

    RÉGLAGES DE L'INTERRUPTEUR DIP Mode Marche Mode Relais 1 Temporisation déclenchement Alertes audibles Temporisation Relais 2 Activé Test/20 min Désactivé 5 minutes 15 minutes Mode Marche du relais 1 30 minutes Mode passage Alertes audibles Marche manuel Sensibilité IRP Marche automatique Mode passage DW-200 uniquement : Activé...
  • Page 10: Mode Service

    Réinitialisation sur les réglages par défaut Utilisez les tableaux de réglages de l'interrupteur DIP à la page précédente pour réinitialiser sur les réglages par défaut. Pour réinitialiser le DW, maintenez enfoncé le bouton MARCHE/ARRÊT du relais 1 pendant 10 secondes, jusqu'à ce qu'un triple bip se fasse entendre. Cette opération permet de réinitialiser le détecteur et de désactiver le contrôle du niveau de luminosité...

Ce manuel est également adapté pour:

Wattstopper dw-100-347Wattstopper dw-200

Table des Matières