No: 23121 – 07/16 rev. 2
Catalog Numbers • Les Numéros de Catalogue • Los Números de Catálogo: LMDW-101, LMDW-102
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
Models ending in -U are BAA and TAA compliant (Product produced in the U.S.)
This unit is pre-set for Plug n' Go™ operation, adjustment is optional.
For full operational details, adjustment and more features of the product, see the DLM System Installation Guide provided with Wattstopper room
controllers, and also available at www.legrand.us/wattstopper.
Installation shall be in accordance with all applicable regulations, local and NEC codes. Wire connections shall be rated suitable for the wire size
(lead and building wiring) employed.
For Class 2 DLM devices and device wiring: To be connected to a Class 2 power source only. Do not reclassify and install as Class 1, or Power and
Lighting Wiring.
Do not apply cleaning solvent directly onto unit. Apply cleaning solvent onto a cloth, then wipe the unit to clean it..
COVERAGE PATTERN
Do not obstruct the lens.
NOTE: Plus 10° above horizon.
30'
(9.1m)
4 ft
20'
SIDE
(6.1m)
VIEW
40 ft
35 ft
25 ft
TOP
180°
VIEW
25 ft
35 ft
40 ft
5 ft
25 ft
40 ft
Down
On/Off
Button
IR Window
PIR
Coverage
Major motion
Minor motion
Ultrasonic
Coverage
Major motion
Minor motion
Wattstopper
DLM Dual Technology Wall Switch Occupancy Sensor
Interrupteur mural avec détecteur de présence à technologie DLM double
Sensor e interruptor DLM con tecnología dual
Quick Start Guide • Guide de démarrage rapide • Guía de inicio rápido
Voltage .............................................................................. 24VDC
Current Consumption ...........................................................20mA
Power Supply ................................. Wattstopper Room Controller
Connection to the DLM Local Network .................... 2 RJ-45 ports
DLM Local Network Characteristics when using LMRC-11x/2xx
room controllers:
Environment ................................................. For Indoor Use Only
Patent Pending
BUTTONS AND INDICATORS
Lens release
LMDW-101
PIR Lens
Up
Select
Configure
Button LED
PIR Detection LED
Ultrasonic Detection LED/
Sensor Binding LED
®
SPECIFICATIONS
Provides low voltage power over Cat 5e cable (LMRJ).
Supports up to 24 communicating devices, including 4
LMRC-10x or LMPL-101 max per each DLM Local Network.
Free topology up to 1,000ft of low voltage cable.
Operating Temperature .................32° to 131°F (0° to 55°C)
Storage Temperature ...................23° to 176°F (-5° to 80°C)
Relative Humidity .......................5 to 95% (non condensing)
WARNING: Do Not Install To Cover
a Junction Box Having Class 1, 3 or
Power and Lighting Circuits.
MOUNTING

Publicité

Table des Matières
loading

Sommaire des Matières pour LEGRAND WattStopper LMDW-101

  • Page 3: Spécifications

    Alimentation électrique ....Wattstopper contrôleur de pièce fourni avec le Wattstopper contrôleurs de pièce et aussi disponible au Connexion au réseau local DLM ........2 ports RJ-45 www.legrand.us/wattstopper. Caractéristiques du réseau local DLM pendant l'utilisation des contrôleurs de pièce LMRC-11x/2xx: L'installation doit être effectuée conformément à tous les règlements La basse tension est générée par le câble Cat 5e (LMRJ);...
  • Page 4: Diagramme De Couverture

    ATTENTION: POUR CONNECTER UN ORDINATEUR AU RÉSEAU DLM LOCAL, UTILISER LA LMCI-100. NE BRANCHEZ JAMAIS LE RÉSEAU DLM LOCAL À UN PORT ETHERNET – CELA POURRAIT ENDOMMAGER LES ORDINATEURS AINSI QUE LES AUTRES ÉQUIPEMENTS CONNECTÉS. BOUTONS ET INDICATEURS DIAGRAMME DE COUVERTURE MONTAGE MISE EN GARDE : Ne pas Ne pas obstruer la lentille.
  • Page 5: Dépannage

    MODIFIER LES PARAMÈTRES DU DÉTECTEUR Les paramètres des détecteurs de présence peuvent être modifiés directement dans le LMDW ou en utilisant le logiciel LMCS-100 ou l’interface de gestion LMSM. Pour modifier les paramètres directement sur le LMDW, retirer la lentille pour exposer l’affichage, puis utiliser un petit tournevis ou un trombone pour naviguer dans les menus avec les boutons Fonction et Configurer et modifier les valeurs avec les boutons Oui et Non.

Ce manuel est également adapté pour:

Wattstopper lmdw-102Wattstopper lmdw-102-w

Table des Matières