6. Timer
7. After completing steps 3 to 6 above, press the Filter
lock in the value.
Note:
Your new settings will be cancelled if you press the Mode (Return) button
before pressing the Filter
button
8. Press the Mode (Return) button
screen.
9. Press the Timer On/Off button
the timer is running, the timer value is visible on the display. Be sure
that the timer value is visible and appropriate.
<Viewing the Current Simple Timer Settings>
TIMER
1. Be sure that the simple timer indicator is visible on the screen (at
2. Press the Timer Menu button
screen (at
).
• If the ON or OFF simple timer is running, the current timer value will
appear at
.
• If ON and OFF values have both been set, the two values appear
alternately.
3. Press the Mode (Return) button
return to the standard control screen.
<To Turn Off the Simple Timer>
Press the Timer On/Off button
pears on the screen (at
).
°C
<To Turn On the Simple Timer>
Press the Timer On/Off button
ible at
.
°C
Examples
If ON and OFF times have both been set at the simple timer, operation
and display are as indicated below.
Example 1:
Start the timer : ON time is set earlier than OFF time.
ON Setting : 3 hours
OFF Setting : 7 hours
Hr
ON
AFTER
SIMPLE
Hr
AFTER
OFF
˚C
˚C
SIMPLE
SIMPLE
button
.
to return to the standard control
to start the timer countdown. When
Timer Setting
Hr
ON
AFTER
OFF
SIMPLE
, so that the "Monitor" appears on the
to close the monitor display and
so that the timer setting no longer ap-
°C
SIMPLE
so that the timer setting becomes vis-
Hr
ON
AFTER
°C
SIMPLE
At Timer Start
Display shows the timer's ON setting (hours
remaining to ON).
At 3 hours after timer start
Display changes to show the timer's OFF set-
ting (hours remaining to OFF).
The time displayed is OFF setting (7 hours) –
ON setting (3 hours) = 4 hours.
At 7 hours after timer start
The air conditioner goes off, and will remain
off until it is restarted.
to
Example 2:
Start the timer : OFF time is set earlier than ON time.
ON Setting
: 5 hours
OFF Setting : 2 hours
Hr
AFTER
˚C
˚C
Hr
AFTER
˚C
˚C

6.1.3. Auto Off Timer

This timer begins countdown when the air conditioner starts and shuts
the air conditioner off when the set time has elapsed.
).
Available settings run from 30 minutes to 4 hours in 30-minute inter-
vals.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2. The Auto Off timer will not operate when any of the following conditions
is in effect.
The timer is off; the system is in malfunction state; a test run is in
progress; the remote controller is undergoing self-check or remote con-
troller check; the user is in the process of selecting a function; the user
is in the process of setting the timer; the system is under central control.
MENU
BACK
MONITOR/SET
PAR-21MAA
(Under these conditions, On/Off operation is prohibited.)
<How to Set the Auto Off Timer>
1.Be sure that you are at a standard control screen, and that the Auto Off
timer indicator is visible in the display (at
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller (see
8.[4]–3 (3)) timer function setting.
2. Hold down the Timer Menu button
Up" appears on the screen (at
(Note that each press of the button toggles the display between "Set
Up" and "Monitor".)
3. Press the appropriate Set Time button A as necessary to set the OFF
time (at
).
4. Press the Filter
button
Note:
Your entry will be cancelled if you press the Mode (Return) button
pressing the Filter
button
5. Press the Mode (Return) button
and return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately. Be sure to check that the timer setting appears cor-
rectly on the display.
OFF
At Timer Start
Display shows the timer's OFF setting (hours
SIMPLE
remaining to OFF).
At 2 hours after timer start
ON
Display changes to show the timer's ON set-
ting (hours remaining to ON).
SIMPLE
The time displayed is ON setting (5 hours) –
OFF setting (2 hours) = 3 hours.
At 5 hours after timer start
The air conditioner comes on and will continue
SIMPLE
to run until it is turned off.
AFTER
OFF
AUTO OFF
TEMP.
ON/OFF
ON/OFF
FILTER
DAY
CHECK
TEST
CLOCK
OPERATION
CLEAR
Timer Setting
AFTER
OFF
AUTO OFF
).
for  seconds so that the "Set
).
to lock in the setting.
.
to complete the setting procedure
before
11