WMBUS Pulse - Guide utilisateur / User guide version V2.2.0
0x30
Keep Alive frame
0x46
Data Frame
0x47
Alarm frame
0x48
Periodic frame with 1 hour-history
0x48 (x3) Periodic frame with 24 hours-his-
tory
• 24 hours elapse since the start-up of the product or since the last transmission of this
frame (5 minutes in TEST mode)
• Start-up of the product (RUN mode)
• Exit from the configuration mode (AT command)
• Transmission period reached (period defined by register S301)
Exceeded flow threshold on one of the two channels (sending only if the exceeded flow
control is enabled by writing a non-zero value in the S326 or S327 registers).
1 hour elapses since the start-up of the product or since the last transmission of this frame
This frame is sent only if the history feature is activated in register S321.
24 hours elapse since the start-up of the product or since the last transmission of this frame
This frame is sent only if the history feature is activated in register S321.