Aim TTi MX100Q Instructions page 46

Masquer les pouces Voir aussi pour MX100Q:
Table des Matières

Publicité

Voltage Programming
Speed MX100QP only:
(Typical figures)
35V 3A
16V 6A
70V 3A
35V 6A
Output Protection:
Over-voltage Protection
(OVP) Trip:
Over-current Protection
(OCP) Trip:
Over-temperature
Protection (OTP) Trip:
METER SPECIFICATIONS (Each Output)
Voltage/Current Meters
Voltage
Current
Current Meter Averaging User selectable On/Off per output with High, Medium or Low settings
V x A:
SETTING MEMORY STORES
Stores for Individual
Outputs:
Stores for All Outputs:
USER INTERFACE
Display:
Soft Keys:
Home Screen:
Individual Screens:
Numeric Setting:
Spin Wheel Setting:
Menu Screen
Help Text
Maximum time required for output to settle within 1% of its total excursion
(for resistive load). Excludes command processing time.
90% Load
Up
10ms
Up
10ms
Up
25ms
Up
10ms
Output will withstand an applied forward voltage of up to 50V (O/P1, O/P2),
or 80V (O/P3, O/P4). Reverse protection by diode clamp for reverse
currents up to 3A.
Outputs 1&2: 1V to 40V. Output 3&4: 1V to 80V. Output trips off for OVP.
Resolution 100mV. Response time: typically 100us. Accuracy: ± (2% + 0.5V)
Measure-and-compare over-current protection is implemented in firmware.
Output trips off for OCP. Setting resolution: 10mA. Response time: typically
500ms. Accuracy: ± (0.3% + 2digits)
The output will be tripped off if a fault or blocked ventilation causes the
internal temperature to rise excessively.
5 digit meters for O/P 1 & O/P2; O/P 3 & O/P 4, 4 digit voltage meters
O/P 3 & O/P 4(70V).
Resolution: O/P1, O/P2, O/P3 & O/P4 (35V): 1mV; O/P3 & O/P4 (70V):
10mV
Accuracy: 0.1% of reading ± 2 digits
Resolution: 0.1mA
Accuracy: 0.3% of reading ± 5 digits
O/P1 & O/P2: 5-digits. Resolution 0.001W to 100W, 0.01W above 100W.
O/P3 and O/P4: 5-digits. Resolution 0.01W. Accuracy: 0.5% of reading ±
3 digits
50 store positions for each output. Values stored are Range, Voltage,
Current, OVP and OCP
50 store positions operating on all four outputs simultaneously.
Values stored are Range, Voltage, Current, OVP, OCP, Output On/Off,
Current Meter Averaging, Multi-On/Multi-Off Setup
White on black backlit graphic LCD, 340 x 112 pixels.
Multiple font sizes and graphic icons.
Eight illuminated multi-function keys annotated from the display.
Simultaneous display of meters and settings for all outputs.
Direct access to voltage or current setting for any output.
Display of meters and extended settings for an individual output (meters
in larger font). Direct access for all settings for that output.
Floating point numeric entry of voltage, current, OVP or OCP.
Voltage, current and other parameters can be adjusted using the spin
wheel in quasi-analog fashion. Wheel can be disabled.
System level functions are selected from a scrollable list.
Multi-page help text is available for system level functions.
Page 45
No Load
10ms
Down
10ms
Down
12ms
Down
10ms
Down
90% Load
No Load
60ms
1400ms
10ms
1000ms
300ms
1400ms
20ms
1400ms