D. Vortice Punto Pull Cord NORMAL / AUTOMATIC
This model is equipped with a pull-cord for
switching it on and off manually.
E. Vortice Punto T HCS NORMAL / AUTOMATIC
This model has a preset humidity sensing circuit
that switches it on when the relative humidity
exceeds 65%. The circuit is also equipped with a
timer that can be set at between 3 and 20 minutes
by adjusting the trimmer (see fig. 14). The unit
switches on automatically a few seconds after the
light is switched on and continues to run for the
preset period of time after the light is switched off.
F. Vortice Punto MHC NORMAL / AUTOMATIC
This model has an MHC microprocessor system for
monitoring relative humidity. The unit is
programmed so that it switches on when room
temperature reaches 20°C and relative humidity
S
T
NORMAL
A
N
D
A
R
AUTOMATIC
D
L
O
NORMAL
N
G
L
I
AUTOMATIC
F
E
This is the complete range of Vortice Punto Models. Not all versions are available in all countries.
12
A
DIAMETER
STANDARD MODEL
TIMER
∅ 090
∅ 100
∅ 120
∅ 150
∅ 100
∅ 120
∅ 150
A
DIAMETER
STANDARD MODEL
∅ 100
∅ 120
∅ 150
∅ 100
∅ 120
∅ 150
exceeds 65%. The microprocessor monitors room
temperature and humidity constantly, calculating
the average temperature over a 48 hour period.
This procedure allows the microprocessor to set
the optimum stop time automatically. This model is
also equipped with a timer that can be set at
between 3 and 20 minutes by adjusting the trimmer
(see fig. 15).
G. Vortice Punto 12 VOLT
NORMAL / AUTOMATIC
IMPORTANT: USE EXCLUSIVELY WITH A
VORTICE 12V POWER SUPPLY UNIT
This model features Class III construction, i.e.
electrical safety is based on the use of a safety low
voltage power supply - a condition that is
guaranteed only when the product is used in
conjunction with VORTICE GA 12V - 12V T - 12V P
- 12V MHC - 12V HCS power supply units.
B
C
D
PIR
PULL CORD
B
C
TIMER
PIR
PULL CORD
E
F
T HCS
MHC
D
E
T HCS
MHC
EN
G
12 V
F

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Punto m 100Punto m 120Punto m 150Punto m 100 12 v

Table des Matières