Télécharger Imprimer la page

Siemens Sitrans Probe LU Guide Rapide page 15

Masquer les pouces Voir aussi pour Sitrans Probe LU:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 73
SITRANS Probe LU Communications: HART
mA Output with Level, Space, and Distance operation
See
Note:
illustration of the mA output with different modes of operation.
• You will need the full manual to acquire the list of applicable parameters.
• Please contact your local representative concerning the availability of the HART DD for
SITRANS Probe LU.
• We recommend that you use SIMATIC Process Device Manager (PDM) to program your
instrument.
Maintenance
SITRANS Probe LU requires no maintenance or cleaning.
Unit Repair and Excluded Liability
For detailed information, please see the inside back cover.
Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
The following instructions apply to the SITRANS Probe LU covered by certificate number SIRA
03ATEX2142X:
1. For use and assembly, refer to the main instructions.
2. The equipment is certified for use as Category 1G equipment.
3. The equipment may be used with flammable gases and vapors with apparatus groups IIA,
IIB, and IIC, and temperature classes T1, T2, T3, and T4.
4. The equipment is certified for use in an ambient temperature range of –40 °C to +80 °C.
5. The equipment has not been assessed as a safety related device (as referred to by
Directive 94/9/EC Annex II, clause 1.5).
6. Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 60079-14 and EN 60079-
17 in Europe).
7. Repair of this equipment shall be carried out by suitably trained personnel in accordance
with the applicable code of practice (e.g. EN 60079-19 within Europe).
8. Components to be incorporated into or used as replacements in the equipment shall be
fitted by suitably trained personnel in accordance with the manufacturer's
documentation.
7ML19985QR81
SITRANS Probe LU (HART) – QUICK START MANUAL
on page 10 for an
(continued on next page)
Page EN-13

Publicité