Dhollandia DH-LSP Instructions De Montage page 49

300-500kg
Masquer les pouces Voir aussi pour DH-LSP:
Table des Matières

Publicité

EN
S
Thoroughly grease all grease nipples in the
various articulations with acid-free grease, ac-
cording to the grease plan in the annex.
Fit all features that will create a safe working environment
for the operator, and the strangers in public traffic: [See
Fig. 9.10]
1. If a wander lead with spiral cable is adopted as auxil-
iary control unit, clearly and permanently mark the safe
-working zone on the loading floor of the vehicle, and
on the platform surface, according to the instructions
given in FIT-ELEC-OPTION-2008-02A.
2. Fit the platform flags and / or check the correct work-
ing order of the electric flashing lights on the platform.
3. Apply red/white reflective marker tape on both sides of
the platform.
4. Apply the sticker with the operation instructions near
the control box, in direct sight of the operator when
using the HTL.
Execute the complete put-into-service test, on
the basis of the CHECKLIST FOR WEIGHT
TEST AND COMMISSIONING included in
chapter 3 of the user's manual.
DHOLLANDIA
9.9 - S243.B
9.10
49
!
!

Publicité

Table des Matières
loading

Table des Matières