3 Remove protection plugs (2) from the fittings on the
rear part of the helm.
4
Make hydraulic hoses (3) pass through rear flange (4), dashboard (5) and front flange (6), then
connect them to the helm (20Nm - 15 lb ft).
WARNING
Keep the pipes far from heat sources and from chemical substances.
Protect the pipes that must pass through bulkheads by using suitable
thru hulls. The bends must be perfectly smooth; any bent pipe or dent
would prevent the hydraulic oil passage.
WARNING
Keep clean. Make sure that working areas are free from dust and dirt.
The protective plugs of threaded holes must be removed only before the
connection of fittings and pipes. Make sure that pipes are perfectly clean
and free from swarf. If copper or steel pipes are used, cleaning is
mandatory. If the installer uses pipes that are different from those
indicated in this manual, he must take full responsibility for it.
WARNING
At the end of the installation make sure that the pipes do not interfere with the
engine and with fixed or mobile parts of the boat or of the steering system
itself.
WARNING
The minimum bending radius of the pipes is 250 mm
pipe bending could break them by compromising the good operation of
the system. If necessary, replace the damaged pipe.
3
Connect the hydraulic hoses ULTRAFLEX kit OB-MD as shown in the picture on page 18 for single station
applications and on page 20 for dual station applications.
As far as tools are concerned, please refer to the installation manuals of KIT OB-
CAUTION
SVS and KIT OB-MD.
Never exceed the recommended torque of 20Nm (15 lb ft) to prevent the hydraulic
WARNING
system from being damaged.
4