8. SERIAL OUTPUT

Specifications
RS-232 output for the transmission of the weight data
ASCII code
Baud 4800 (selectable from 600 - 9600)
data bits 8 – n – 1
No Parity
Connector:
9 pin (female)
Pin 2:
RECEPTION
Pin 3:
TRANSMISSION
Pin 5:
GND

8.1 TRANSMISSION MODES

The transmitted data format varies depending on the selected transmission mode (see step F4, section 7).
"PAUTO" AND "P PRT" MODE
Totalisation Mode
In the normal weighing operations when one is accumulating the weight the data format depends on the printer format
selected in the F4 step, see section 7:
LAB 0
NO.
1
G
400.0 kg
When the totals are recalled from the storage (see section 6.6.3) the data format is the following:
"P CONT" MODE
In this transmission mode the instrument transmits continuously the data format depending on the protocol selected in the
F4 step, see section 7:
Cont 1 protocol
Normal mode
ST,GSXXX.XXXXkg<CR><LF>
Counting mode
PCS:XXXXXXX pcs<CR><LF>
Cont 2 protocol
Not used in this application
LAB 1
LAB 2
NO.
1
NO.
N
200.0 kg
G
T
200.0 kg
Total 1000.0 kg
G
400.0 kg
Progressive of totalisations
ST for stability, US for instability
GS for gross weight, NT for net weight
Number of pieces
LAB 3
1
NO.
400.0 kg
N
200.0 kg
T
200.0 kg
G
400.0 kg
Total 1000.0 kg