F2 Unt" - Configuration Of Secondary Units Of Measure; F3 Off" - Enabling Display Backlighting And Acoustic Alarm - Scale House AFW Serie Manuel Opérateur

Balance avec colonne / indicateurs de poids
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Set Hi
SETTING UPPER THRESHOLD
By pressing ZERO the display shows "000.000kg", with the first digit blinking, and it's therefore possible to configure
the upper threshold:
-
Use the F key to clear the value, the TARE key to increase the value of the digit, the U key to go on the previous
digit and the SMPL key to go on the following digit.
-
Confirm with ZERO the entered value or press PRINT/M+ to exit without confirming.
7.3 "F1 toL" – CLEARING TOTAL
toCLr
CLEARING TOTAL
By pressing ZERO it's possible to clear the accumulated total weight.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
to P-C
Not used in this application.
to Prt
Not used in this application.
7.4 "F2 Unt" – CONFIGURATION OF SECONDARY UNITS OF MEASURE
By pressing ZERO it's possible to choose the units of measure for the conversion function (see section 6.8), enabling
(on) or disabling (oFF) the suggested secondary units of measure:
1) The display proposes the first secondary unit of measure to be enabled or disabled.
2) Press TARE to change the options and confirm with ZERO, or press PRINT/M+ to exit without confirming and
pass to the following unit.
3) The display proposes the 2nd secondary unit to be enabled or disabled.
4) Proceed as described in point 2 up until the last proposed unit of measure.
7.5 "F3 oFF" – ENABLING DISPLAY BACKLIGHTING, AND ACOUSTIC ALARM
bL
DISPLAY BACKLIGHTING
By pressing ZERO it's possible to programme the functioning mode of the backlighting.
Press TARE to change the options:
EL oFF backlighting always off
EL on
backlighting always on.
EL AU
backlighting on only when the weight is greater than 20d or when a key is pressed. When a key is pressed,
if the weight is less than 20d, the backlighting remains active for 5 seconds.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
bEEP
ACOUSTIC ALARM
By pressing ZERO it's possible to decide whether the acoustic alarm should enable when the "OK" symbol is on or
when the "HI" or "LO" symbols are on.
Press TARE to change the options:
bP 1 acoustic alarm disabled
bP 2 active acoustic signal with active "OK" symbol.
bP 3 active acoustic signal with active "HI" or "LO" symbol.
Confirm with ZERO or press PRINT/M+ to exit without confirming.
13

Publicité

Table des Matières
loading

Table des Matières