6.7.2 ACOUSTIC ALARM IN CORRESPONDENCE OF THE HI-OK-LO LIMITS
One can decide if the acoustic alarm should enable when the "OK" symbol is on or when the "HI" or "LO" symbols are
on. To choose the alarm enabling mode, see section 7.6.

6.7.3 VISUAL INDICATION OF THE WEIGHT CHECK

Put a weight on the plate of the scale.
The indication symbols will enable depending on which thresholds have been configured:
WITH BOTH THRESHOLDS CONFIGURED
-
The HI symbol of the LCD display will turn on when the detected weight exceeds the UPPER WEIGHT
THRESHOLD.
-
The OK symbol of the LCD display will turn on when the detected weight is between the LOWER WEIGHT
THRESHOLD and the UPPER WEIGHT THRESHOLD.
-
The LO symbol of the LCD display will turn on when the detected weight is less than the LOWER WEIGHT
THRESHOLD.
WITH THE UPPER THRESHOLD CONFIGURED AND THE LOWER THRESHOLD = 0
-
The OK symbol of the LCD display will turn on when the detected weight exceeds the UPPER WEIGHT
THRESHOLD.
-
The LO symbol of the LCD display will turn on when the detected weight is less than the UPPER WEIGHT
THRESHOLD.
WITH THE UPPER THRESHOLD = 0 AND THE LOWER THRESHOLD CONFIGURED
-
The HI symbol of the LCD display will turn on when the detected weight exceeds the LOWER WEIGHT
THRESHOLD.
-
The OK symbol of the LCD display will turn on when the detected weight is less than the LOWER WEIGHT
THRESHOLD.
NOTES
-
The weight check function is enabled when the limit values are entered. To disable the function one should set the
limit values at zero.
-
The function is not valid when one enters a lower limit greater than the upper limit.
-
The weight check is enabled with a weight greater than the minimum weight (20d).

6.8 UNIT OF MEASURE CONVERSION

By pressing various times the U key the conversion into the configured secondary units of measure takes place (see
section 7.4); the relative symbol will turn on in the display (see section 5).
NOTE:
- The function is not available if the counting function is enabled or if the number of decimals of the weight is less than
3.
- With APPROVED instrument the weight in secondary units is displayed for 5 seconds, after which the display goes
to the scale unit of measure.

7. SET-UP ENVIRONMENT

The scale has various parameters that can be configured in the SET-UP environment.
To enter in the SET-UP environment press the F key in the weighing phase.
- The display will show the first function, " F0 H-L ":
- Pressing the TARE will cycle through the other functions.
- Pressing ZERO will allow you to set the function. It may be necessary to either use TARE or set a value using the U
key and the SMPL key to move the active digit and then using the TARE key to increment a digit, followed by the ZERO
key to enter the value.
- Use the PRINT/M+key to leave a parameter unchanged or to escape set-up environment.