P4 Chk" - Enabling Filter And Enabling Totalisation In Unloading - Scale House AFW Serie Manuel Opérateur

Balance avec colonne / indicateurs de poids
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IN CASE THE ZONE OF USE IS DIFFERENT FROM THE CALIBRATION ZONE ONE SHOULD:
1) Enter in the SET-UP environment of the scale (press the F key in the weighing phase).
2) Enter in the ProG >> P3 Pro >> SEtGrA step and set the gravity acceleration value for the
CALIBRATION ZONE
3) Carry out the calibration as previously described.
4) Save and exit from the SET-UP environment (press many times the PRINT/M key).
5) Enter the SET-UP environment of the scale and enter the ProG >> P3 Pro >> SEtGrA step and set the
gravity acceleration value for the ZONE OF USER.
6) Save and exit the SET-UP environment (press many times the PRINT/M key).
7) The weight error caused by the error of a different gravitational attraction value between the calibration
zone and the zone of use is corrected automatically.
7.8.3 "P3 Pro" – VISUALISATION OF A/D CONVERTER POINTS AND MANUFACTURER'S
CONFIGURATION
(*) With approved instrument the parameter is read-only.
(*) tr i
For use of the manufacturer.
CoUnt
A/D CONVERTER POINTS
By pressing ZERO the instrument shows the A/D converter points relative to the weight on the scale.
Press PRINT/M+ to exit the step.
(*) rESEt
For use of the manufacturer.
(*) SEtGrA GRAVITY ZONE AND ZONE OF USE
Through this step one selects the acceleration value of calibration and of use of the instrument:
Manual entry of the g value: one may manually enter the gravitational acceleration value; one must modify
the 6 decimal digits of the gravitational acceleration.
In case one enters a wrong g value: the minimum decimal value is suggested (9,75001); a wrong value is any
decimal number that is not between 9,75001 and 9,84999 (inclusive).
7.8.4 "P4 CHK" – ENABLING FILTER AND ENABLING TOTALISATION IN UNLOADING
By pressing ZERO one chooses whether to enable the filter intervention for the stability of the weight indication
or enable the totalisation in unloading function, useful for totalising with a negative net weight.
Press TARE to change the options:
ModE 1
Filer disabled and totalisation in unloading disabled.
ModE 2
Filter enabled and totalisation in unloading disabled.
ModE 3
Filter disabled and totalisation in unloading enabled.
ModE 4
Not used in this application.
Confirm with ZERO, or press PRINT/M+ to exit without confirming.