OPTIONALS
EXTRA FUNCTIONS WITH
!! FEED THE EXP CARD IN WHEN POWER IS NOT SUPPLIED !!
LÉGENDE
CAPTION
TR
=> Adjustment trimmer for the courtesy light time
1-2 => 24Vac power supply for photocells, FOTOOSTA units etc....
3-4 => Traffic light 1 contact
5-6 => Traffic light 2 contact
7-8 => Courtesy light contact
9
=> Photocell 2 contact (NC)
10
=> Pedestrian opening command (NO)
11
=> Free contact
12
=> Common unit
EXPANDER
D2
photocell 2 contact signal
D3
pedestrian contact signal
D4
free
D5
voltage available
N.B.: LED D2 and LED D5 must always be turned on for a correct functioning .
PEDESTRIAN OPENING BUTTON (10-12)
This command operates the partial opening of the gate and Its closing. When the gate Is
partly open, it is not possible to operate its total opening using the pedestrian command.
It is first necessary to close the gate than to open it totally.
It enables exclusively the pedestrian opening and closing following the jogging mode
(open-stop-close-stop-etc...).
LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING
When the gate is closet and the closing limit switch is engaged
1 - First position the DIP2 on mode ON (the LED DL5 blinks quickly) and then DIP1
on mode ON (The LED DL5 blinks slowly).
2 - Press the pedestrian button (10-12) => The sliding gate opens.
3 - Press the pedestrian button to stop the travel (thereby determining the gate opening).
4 - Wait the time you want the gate to remain open (excluded by DIP9 on OFF), then
press the pedestrian button to start the closing.
5 - Position DIP1 and 2 on mode OFF after the closing limit switch has been reached.
Safety devices are active during the programming and their intervention stops it (the LED
blinks no more but remains constantly turned on).
To repeat the programming, position DIP1 and 2 on mode OFF, close the gate and
repeat the procedure described above.
AUTOMATIC PEDESTRIAN CLOSING
Pause times before the automatic pedestrian closing of the gate are set during the
programming procedure.
The max. pause time is 5 minutes.
You can start or stop the pause time using DIP9 (ON starts).
PHOTOCELL 2 (9-12)
If it detects an object during the opening cycle, it then operates the closing of the gate at
the end of the interposition. If it detects one during the closing cycle, it then operates the
opening at the end of the interposition.
This function is particularly helpful when you want the gate to close immediately after you
passed it. If it is not used, jumper the terminals 9-12.
COURTESY LIGHT (7-8)
It is possible to supply 24Vac power to the coil of a relay, so as to feed one lamp or more
for a minimum period of 1 second and for a maximum period of 4 minutes (controlled by
the TR trimmer fitted on the EXPANDER card).
The relay is activated at every opening or closing.
When the closing Is finished, the traffic light turned off.
EXPANDER
(ACG5470)
CARD LED SIGNALS
D5
D4
D3
D2
TRAFFIC LIGHT CONTROL
When the gate is closed, the traffic light is turned off.
The red light (3-4) turns on when the gate opens.
The green light (5-6) turns on when the gate is open and the red light turns off.
The green light remains turned on until the automatic closing starts.
When the gate closes, the green light turns off and the red light turns on.
INVERTER
!! REMOVE THE MOTOR CAPACITOR !!
Connect the motor wires directly to the INVERTER card (lead blue=>terminal U).
The INVERTER allows for => the thrust force adjustment, the gradual start, the
adjustable max. speed, the slowing-down while approaching and the breaking when the
limit switch is reached.
The capacity of K1800 becomes 900Kg/1980lbs.
CARD (ACQ9092)
HEATER
This device controls the heating of the operating device when this is installed in places
with very low temperatures.
ACG6082 - 433
ACG7026 - 91
RADIO TRANSMITTER MOON
MOON 91 (30,925MHz) - 2CH Code ACG7025 - 4CH TX91 Code ACG7026
* Ref. Min. Certificate P.T. of EC Inspection N. EMC/98/IST/012
* Min. Authorization P.T. DGPGF/SEGR/2/07/336915/FO
* EC CERTIFICATE OF COMPLIANCE OF THE KIND
* CERTIFICATE OF CONFORMITY (GERMANY)
Pag. 19 di 28