ELECTRONIC BOARD KS
BC07050
OPERATING MICROSWITCH
DIP 1
Checking the rotation direction of the motor (ON)
DIP 2
Timing (ON)
DIP 3
Pause time before the automatic closing (ON)
DIP 4
Jogging radio receiver (OFF) - automatic (ON)
DIP 5
Single impulse command (K BUTT) jogging (OFF) - automatic (ON)
DIP 6
Photocells always active (OFF) - Photocells active only on closure (ON)
DIP 7
Encoder for the PLUS model (ON - operated)
DIP 8
Pre-blinking (ON) - Normal blinking (OFF)
DIP 9
Pause time before the automatic pedestrian closing (ON)
DIP 10 Electronic brake (ON-operated)
DIP 11 Gradual start (ON- operated)
DIP 12 230V Motor (OFF) 120V (ON)
IMPORTANT SAFETY INSTRUCTIONS
FOR THE INSTALLATION
1° - Install a thermal magnetic switch (omnipolar, with a minimum contact opening of 3
mm) before the control board, in case this is not provided with it. The switch shall be
guaranteed by a mark of compliance with international standards.
2° - As far as the cable section and the cable kind are concerned, RIB suggests to use
an NPI07VVF cable, with a minimum section of 1,5mm
the IEC 364 standard and Installation regulations In force In your Country.
N.B.: THE SYSTEM MUST BE GROUNDED
Data described by this manual are only Indicative and RIB reserves to modify them at
any time.
Install the system complying with current standards and regulations.
J1 => EXP.
J2 => SEC.TRANSF.
J3 => L1 - N
J4 => PRI.TRANSF. Connector for primary transformer
J5 =>
J6 => SEC.LOCK
J7 => ENCODER
J8 => CAPACITOR Connector to the capacitor
J9
J10 => MOTOR
J11 =>
J12
J13 => INVERTER Connector for the logic of the INVERTER card (optional)
J14
J15 => RADIO
J16 => HEATER
J17 => INVERTER Connector for the INVERTER card power supply (Optional - DO
The torque is regulated by rotating the Trimmer TORQUE, varying the output voltage of
motor ends,(when rotated clockwise, more torque Is transmitted to the motor).
Such torque Is automatically Included 3 seconds after the start of every operating cycle.
This allows the motor to have the maximum pickup when it starts.
If DIP 10 is ON, the system shall brake once the total opening or closing have been
carried out, so to avoid the inertia that would damage the gear In the event of an Impact
against the mechanical stops.
If DIP 11 is ON, a gradual movement is enabled at every operation start.
This function is not active after the encoder or another safety device detects an obstacle.
DL1 photocells contact (NC)
DL2 stop contact (NC)
DL3 opening limit switch contact (NC)
DL4 closing limit switch contact (NC)
DL5 programming operated
2
, and to follow, In any case,
DL6 gate on opening "OPEN" (green)
DL7 gate on closure "CLOSE" (red)
DL8 manual release safety device (NC)
DL9 Checking the encoder operation
4 - CONNECTIONS
Connector for EXP card
Connector for secondary transformer
Power supply 230 Vac 50/60 Hz
DO NOT TOUCH THE JUMPER !
IF IT IS REMOVED THE OPERATOR DOESN'T MOVE !
Connector to the manual release safety device
Connector to the Encoder (on K PLUS)
LSO
Limit switch contact stopping the motor opening
COM.
Contacts common unit
LSC
Limit switch contact stopping the motor closing
Connector to the Motor
Blinker (max. 40W )
AERIAL
Radio Antenna
COM Contacts common unit
PHOT.1 NC
Photocells contact (NC)
STOP
Contact of the stop button (NC)
OPEN
Contact of the opening button (NO)
CLOSE
Contact of the closing button (NO)
K BUTT.
Contact of a single impulse (NO)
A*A
24 Vac accessories power supply
SIGNAL
Warning light - gate open 24Vdc
Buzzer
Connector for radio receiver 24Vac
Connector for Heater Card
NOT ALTER THE SAFETY DEVICE ! )
TORQUE - ELECTRONIC TORQUE REGULATOR
ELECTRONIC BRAKE (suggested operation)
GRADUAL START (suggested operation)
LED SIGNALS