5 - CHECKING THE ROTATION DIRECTION OF THE MOTOR
N
This control is carried out to facilitate the installation of the system or any possible future
control.
G
L
1 - After you positioned the limit switch cams on the rack, (Fig.7 page 4), set Dip1 on
I
mode ON. The LED DL5 starts blinking.
2 - Press and keep the button PROG. (the gate is now controlled with manned operation:
S
open-stop-close-stop-open-etc.). THE GREEN LED DL6 "OPEN" turns on and the
H
gate opens and stops after having reached the limit switch cams. If this does not
happen, release the button and invert the two cables of the motor.
3 - Press the button PROG. and keep it. THE RED LED DL7 "CLOSE" turns on and the
gate closes and stops after it reaches the limit switch cams.
4 - At the end of the control, position DIP1 on mode OFF. The LED DL5 turns off,
signalling you exit from the control.
NB: The encoder and the photocells are not active during this control.
K PROGRAMMING WITH ENCODER (K PLUS)
The programming can be carried out regardless of the gate position.
1 - Position the micro switch Dip 2 on mode ON => the LED DL5 emits short blinkings.
2 - Push the button PROG. => the gate opens closes and opens automatically 2 seconds
after It closed. When the opening cycle Is terminated, It stops. Wait as long as you
want the gate to remain open (excluded by DIP3 OFF)
3 - Push the button PROG. to command the gate closing (also the pause time count
before the automatic closing stops - max. 5 minutes).
4 - The gate stops as the closing cam is reached.
5 - WHEN THE TIME PROGRAMMING IS COMPLETED, POSITION DIP 2 ON MODE OFF.
If the INVERTER card is connected to the KPLUS with the KS, the card automatically
controls its slowing-down on approaching and you can also control the operator speed
(read the Instructions enclosed to the INVERTER card).
K PROGRAMMING WITHOUT ENCODER (K)
NB: DIP7 SHALL BE ON MODE OFF!!
This programming is the same as that shown by the previous paragraph.
By connecting the INVERTER card to K with KS, this automatically controls its slowing-
down when approaching, and you can also determine the speed of the operating device
(read the instructions enclosed to the INVERTER card).
OPERATION OF THE OPERATING ACCESSORIES
OPENING BUTTON (with timer function)
When the gate is standstill, the button operates the opening mode. If you push this button
when the gate is on closure, It opens again.
TIMER FUNCTION
This function is useful In the rush hours, when vehicle traffic is slow (e.g. entry/exit of
workers, emergencies In residential or parking areas and, temporary, for removals).
APPLICATIONS
By connecting a switch and/or a daily/weekly timer (in place or in parallel with the opening
button N.O. "COM-OPEN"), it is possible to open the automation or to keep It open, as
long as the switch is on or the timer is activated.
When the automation is open, all operating functions are inhibited.
If the automatic closing Is started, by releasing the switch or at the time set before, the
automation immediately closes; if not, you need to operate a command.
CLOSING BUTTON (COM-CLOSE)
When the gate Is standstill, It operates the closing.
JOGGING OPERATION BUTTON (COM-K BUTTON)
If DIP5 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP5 is ON => It opens the gate when this Is closed. If It Is operated while the gate Is
opening, It has no effect. If It Is operated when the gate is open, it closes the gate and, If It
Is operated while the gate Is closing, It opens the gate again.
If DIP4 is OFF => It cyclically commands open-stop-close-stop-open-etc.
If DIP4 is ON => It opens the gate when this is closed. If It Is operated while the gate Is
opening, It has no effect. If It Is operated when the gate Is open, It closes. If It Is operated
while the gate Is closing, It opens the gate again.
Pause times before the automatic closing of the gate are set with the timing procedure.
The maximum pause time Is 5 minutes.
Pause time can be started or stopped by DIP3 (ON started).
6 - TIMING
RADIO TRANSMITTER
AUTOMATIC CLOSING
SAFETY ACCESSORIES OPERATION
SAFETY ENCODER (KPLUS)
It serves as a safety device both during opening and on closure, with movement
reversion.
DIP 7 (ON) operates the motor with encoder.
If the Encoder does not work (due to a failure In the power supply, disconnected wires,
broken or defective disk), the gate Is not operated.
If the encoder operates the closing or the opening and than gives a reverse command, the
gate stops and reverses Its movement for 1 second. The buzzer buzzes to alarm for 5
minutes and the blinker blinks for 1 minute.
During or after the 5 minutes, when the buzzer alarms, you can make the gate work again
just pressing the operating button you want.
PHOTOCELL 1 (COM-PHOT 1))
If DIP 6 is OFF - The gate does not open if there Is an obstacle within the photocells
range of action.
During operation, photocells work both when the gate opens (by starting the opening
movement again after half a second time), and when It closes (by starting the reverse
movement after one second time).
If DIP 6 is ON - If there Is an obstacle within the photocells range of action when the gate
is closed and its opening Is commanded, the gate opens (during Its opening, photocells do
not work).
Photocells work only while the gate Is closing (by starting Its reverse motion after one
second, even if they are still engaged).
STOP BUTTON
The STOP button stops the gate during any operation.
If you push it when the gate is totally open (or partly open, by using the pedestrian
command), this button temporary excludes the automatic closing (if selected by DIP3 and
DIP9). It Is than necessary to operate another command to make the gate close again.
The automatic closing function Is enabled again with the following operating cycle (if
selected by DIP3 and DIP9).
N.B.: This electric board can supply power ONLY TO BLINKERS WITH (ACG7059)
BLINKING CIRCUIT, with max. 40W lamps.
PRE-BLINKING FUNCTION:
- With DIP8 on OFF => the motor, the blinker and the buzzer start at the same time.
- With DIP 8 on ON => the blinker and the buzzer start 3 seconds before the motor.
BUZZER (Optional)
The buzzer emits an intermittent sound signal during opening and closing cycles.
When safety devices are operated (alarm), the intermittence frequency of this sound
signal Increases.
WARNING LIGHT - GATE OPEN (COM-SIGNAL):
Its function Is to signal when the gate Is open, partly open or not totally closed anyway. It
turns off only when the gate Is totally closed.
This warning signal is not enabled during the programming procedures.
N.B.: If you overuse the push button panels or the lamps, the control board logic
system may be compromised, resulting into a possible operation block.
TECHNICAL DATA
- Temperature range
- Moisture
- Power supply voltage
- Frequency
- Max. power consumption of the card
- Transient power mains drops
- Max. capacity of the warning light - gate open -
- Max. load at blinker output 40W with resistive load
- Available current for photocells and accessories
- Available current for the radio connector
- All inputs must be used as clean contacts without being earthed, because power
supplied is generated In the card and is arranged so as to allow for double or reinforced
Insulation with respect to live parts.
All inputs are controlled by a programmed integrated circuit, that carries out a self-control
cycle every time the gate Is operated.
BLINKER
0 ± 70°C
< 95% without condensation
230V~ ±10%
50/60 H
60 mA
100mS
3 W (corresponding to 1 3W lamp or
to 5 LEDS with 2,2 kΩ
resistance In series)
0,4 A ±15% 24Vac
200mA 12Vdc