Operating Instructions SATA LPS R 2000, SATA LPS RB 2000 RP, SATAminijet 1000 A S HVLP
9.3. Replace the paint needle seals
Material leaks from the gun body inspection hole
If the two paint needle seals are damaged, material can leak from the
gun body inspection hole [1-3], [2-7].
→ Replace the paint needle seal immediately.
Dismantle paint needle seal
■ Unscrew the material flow control [9-1].
■ Remove the spring [9-2].
■ Remove the paint needle [9-3].
■ Use the socket spanner [10-8] to unscrew the packing bolt [10-7] out
of the gun body [10-1].
■ Remove the paint needle seal [10-6], washer [10-5], pressure spring
[10-4], spacer [10-3] and second paint needle seal [10-2].
Mount paint needle seal
Note!
Check for damage and wear and replace with new ones where neces-
sary.
■ Insert the paint needle seal [10-2], spacer [10-3], pressure spring
[10-4],
■ washer [10-5] and second paint needle seal [10-6].
■ Use the socket spanner [10-8] to screw the packing bolt [10-7] into the
gun body [10-1].
■ Insert the paint needle [9-3].
■ Insert the spring [9-2].
■ Screw on the material flow control [9-1].
After installation, adjust material flow according to chapter 8.2.
9.4. Replace the spindle of the round/flat fan control
Only present in SATA LPS RB 2000 RP and SATAminijet 1000 A S
HVLP. Replacement is necessary if air escapes from the round/flat fan
control or if it is no longer possible to adjust the spray fan pattern.
Dismantle spindle
■ Unscrew the countersunk screw [11-5].
■ Pull off the control knob [11-4].
■ Screw the spindle [11-3]out of the gun body using the SATA universal
Attention!