salmson LRE Installation Et Mise En Service page 115

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Classification No.
Electronics
E070 Internal communica-
errors
E071 EEPROM error
E072 Power section/fre-
E073 Impermissible elec-
E075 Charging relay defec-
E076 Internal transformer
E077 24 V operating voltage
E078 Impermissible motor
E096 Infobyte not set
E097 FlexPump data record
E098 FlexPump data record
E121 Motor PTC short-cir-
E122 Interruption to NTC
E124 Interruption to NTC
Impermissi-
E099 Pump type
ble combina-
torics
Tab. 10: Error table
Additional explanations of error
codes
Installation and operating instructions LRE, JRE
Fault
Cause
Internal electronics error
tion error (SPI)
Internal electronics error
Internal electronics error
quency converter
Internal electronics error
tronic module number
Internal electronics error
tive
Internal electronics error
defective
Differential pressure sen-
for differential pres-
sor defective or con-
sure sensor defective
nected incorrectly
Internal electronics error
number
Internal electronics error
Internal electronics error
missing
Internal electronics error
invalid
Internal electronics error
cuit
Internal electronics error
power element
Internal electronics error
electronic module
Different pump types
have been intercon-
nected
Error E021:
Error 'E021' indicates that the pump requires more power than is per-
mitted. To ensure that the motor and electronic module do not suffer
irreparable damage, the drive protects itself by switching the pump
off if an overload lasts more than 1 minute.
The most common causes of this error are a pump that is configured
too small, especially when pumping viscous fluids, or an excessive
volume flow in the system.
When this error code is displayed, there is not an error in the electronic
module.
Error E070; possibly combined with error E073:
If additional signal lines or control lines are connected to the electronic
module, the effects of EMC (immission/interference resistance) may
interrupt communication. This results in error code E070 being displayed.
You can check this by disconnecting all the communication lines
installed by the customer from the electronic module. If the error no
longer occurs, there could be an external interfering signal on the
communication line(s) that exceeds the applicable standard values.
The pump can only return to normal operation once the source of
interference is remedied.
Remedy
Request customer service
Request customer service
Request customer service
Request customer service
Request customer service
Request customer service
Check differential pressure
sensor connection
Request customer service
Request customer service
Request customer service
Request customer service
Request customer service
Request customer service
Request customer service
Request customer service