INSTALLATION MANUAL
1 -
WARNINGS AND SAFETY
After removing the packaging, check the integrity and com-
pleteness of the supply and, otherwise, contact the Riello
Agency that sold the boiler.
The FAMILY CONDENS KIS E bboiler must be installed in ac-
cordance with the regulations in force by a qualified company
which, at the end of the installation process, must issue the
owner with a declaration of conformity certifying that the instal-
lation has been performed according to the best working prac-
tices and in observance of applicable legislation and of the indi-
cations provided by Riello in the present instructions booklet.
The installer must instruct the user about the operation of the
appliance and about essential safety regulations.
The boiler must be used for the use planned by Riello for which
it was designed. Riello declines all contractual and non-con-
tractual liability for injury to persons or animals or damage to
property deriving from errors made during installation, adjust-
ment and maintenance and from improper use.
In the event of a water leakage, shut off the water supply and
promptly contact the Riello Technical Assistance Centre or oth-
er professionally qualified personnel.
From time to time, check the
display; this symbol indicates an incorrect charge pressure.
Otherwise, refer to paragraph "Smart system filling".
Not using the boiler for an extended period of time involves the
execution of at least the following operations:
- turn the main appliance switch and the main system switch
to "off"
- close the fuel and water taps of the heating system
- drain the heating and domestic hot water circuits if there is a
risk of freezing.
The boiler maintenance must be carried out at least once a
year.
This booklet and that of the User are an integral part of the ap-
pliance and therefore should be carefully preserved and should
always accompany the boiler even when it is sold to another
owner or user or when transferred to another system. In case
of loss or damage, please contact your local Riello Technical
Assistance Service for a new copy.
The boiler is built so as to protect both the user and the installer
from any accidents. After each intervention on the product, pay
special attention to the electrical connections, especially the
stripped parts of the wires, which must not protrude from the
terminal board in any way.
Dispose of all the packaging materials in the suitable contain-
ers at the corresponding collection centres.
When disposing of waste, be careful not to harm human health
or employ procedures or methods which may damage the en-
vironment.
At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
Remember that the use of products requiring fuels, electricity and
water necessitates the respect of certain basic safety rules such as:
It is forbidden for children and unassisted unskilled people to
use the boiler.
It is forbidden to activate electric devices or appliances such as
switches, household appliances and so on if you notice a smell
of fuel or unburnt fuel.
4
icon does not light up on the
In this case:
- ventilate the room by opening the doors and windows
- close the fuel shut-off device
- promptly contact the Technical Assistance Centre or other
professionally qualified personnel.
It is forbidden to touch the boiler while barefoot or if parts of
your body are wet.
It is forbidden to carry out any cleaning operations before dis-
connecting the boiler from the electricity supply; to do this, turn
the main system switch to "OFF".
It is forbidden to modify safety and adjustment devices without
the boiler manufacturer's permission and relative instructions.
It is forbidden to pull, detach or twist the electric cables that
emerge from the boiler, even if the boiler itself is disconnected
from the mains supply.
It is forbidden to plug or reduce the size of any openings used
for airing the installation area.
It is forbidden to leave flammable containers and substances in
the room where the boiler is installed.
It is forbidden to disperse and leave packaging material within
children's reach as it may be a potential source of hazard.
It is forbidden to obstruct the condensate outlet.
2 -
DESCRIPTION
FAMILY CONDENS KIS E are a wall-hung condensing boiler with
pre-mix burner and low emission of pollutants for heating and for
DHW, equipped with a stainless steel plate heat exchanger. These
are electronically controlled boilers with automatic ignition, ionisation
flame check and with proportional control system of the gas and air
flows, both in heating and DHW.
These use an aluminium alloy boiler body, have sealed combustion
chamber and, based on the gas discharge accessory used, are clas-
sified in categories B23P, B53P, C13-C13x, C33-C33x, C43-C43x,
C53-C53x, C83-C83x, C93-C93x, 3CEP. The switching of the heat-
ing and DHW modes is performed via a three-way electric valve
which set on DHW when in the rest position. To guarantee the cor-
rect water output in the exchanger, the boiler is equipped with an
automatic by-pass.
The boiler is equipped with:
- Circulator with variable speed (PWM= Pulse-Width Modulation)
- Modulation 1:10, the boiler can automatically modulate the output
power in a maximum and minimum range (see technical data)
- Range Rated - this means the boiler is equipped with a device that
adapts it to the heat requirements of the system, so the boiler out-
put can be adjusted according to the energy needs of the building
- Comfort key that allows the constant temperature of the domestic
cot water (40°C)
- Memory Key that reduces the domestic hot water standby time
- Touch & Go function, activated when the hot water tap is opened
- Semi-automatic heating system filling device
- Microprocessor management and control with self-diagnostics dis-
played by means of a display
- Circulator anti-blocking
- First-level antifreeze (suitable for indoor installations)
- Premix combustion system which ensures a constant air-gas ratio
- Ambient thermostat or programmable timer or local valve prear-
rangement.
- External probe that enables the climate control function
- Prepared for limit thermostat on reduced temperature systems.