THE DATA APPEAR LIKE THAT
1. Clk 24/12: (clock) to choose between the system 24-hours or the system 12-hours.
Press the key
2. APM A/P: (am pm) system 12-hours. "a" for the morning, "p" for the afternoon.
Press the key
In the system 24-hurs, it cannot be changed, showing "—".
3. YEA 00: (year) Introduce the number "12" for "2012". The biggest number is 99.
Press the key
through "1".
4. Mon 00: (month) Introduce the month, "4" for April. The biggest number is 12.
Press the key
through "1".
5. Dte 00: (day) Introduce the number of the day. The biggest number is 31.
Press the key
through "1".
6. Hou 00: (hour) Introduce the hour, "8" for the 8:00. In the system 12-hours, the biggest number is 12. In
the system 24-hours, the biggest number is 23.
Press the key
through "1".
7. Min 00: (minute) Introduce the minute, "30" for 30 minutes. The biggest number is 59.
Press the key
through "1".
8. Sec 00: (second) Introduce the second "30" for 30 seconds. The biggest number is 59.
Press the key
through "1".
9. Day 00: (day) Introduce the number of the day, . "0" for Sunday, "1" for Mondays... The biggest number
is 6.
Setting up division, decimal point, max. capacity and calibration
Press and hold
key, then turn on the scale, to enter division setting.

3.1. DIVISION SETTING

Display shows "d x", then press
Then press
key to conÀ rm, and enter the decimal point setting.

3.2. DECIMAL POINT SETTING

Display shows "p x", then press
to conÀ rm, and enter the maximum capacity setting.

3.3. MAXIMUM CAPACITY SETTING

Display showsa " FULL " around 2-3 seconds then display shows "000.000", the decimal point was set
as 3 decimal points, then press
that will increase the number, then press
repeat the above moves until display shows the maximum capacity.
Then press
key to enter calibration setting.

3.4. ZERO POINT CALIBRATION

Display shows "CaL 0", Do not put any objects on the pan when display shows this, then scale will move to
30
to change the data.
to change the data.
, the decimal digit is added through "1". Press the key
, the decimal digit is added through "1". Press the key
, the decimal digit is added through "1". Press the key
, the decimal digit is added through "1". Press the key
, the decimal digit is added through "1". Press the key
, the decimal digit is added through "1". Press the key
key to select 1, 2, 5, 10, 20, 50.
key to select 0, 0.0, 0.00, 0.000, 0.0000, P.00000. Then press
key to move the Á ashing digits to the right in circle to select the digits
key to increase the number until the number appears, then
ARD
, the other digit is added
, the other digit is added
, the other digit is added
, the other digit is added
, the other digit is added
, the other digit is added
3. CALIBRATION
key