Error Diagnosis
Error
State
__________________________________________________________________________________________________________________
0
Control in the learning cycle
__________________________________________________________________________________________________________________
1
Door neither opens nor closes
__________________________________________________________________________________________________________________
2
Door neither opens nor closes
__________________________________________________________________________________________________________________
3
Door neither opens nor closes
__________________________________________________________________________________________________________________
4
Door neither opens nor closes
__________________________________________________________________________________________________________________
5
Door neither opens nor closes
__________________________________________________________________________________________________________________
6
Door neither opens nor closes
______________________________________________________________________________________________________________
7
Door neither opens nor closes
__________________________________________________________________________________________________________________
9
Door neither opens nor closes
__________________________________________________________________________________________________________________
A
Door neither opens nor closes
__________________________________________________________________________________________________________________
b
Door neither opens nor closes
__________________________________________________________________________________________________________________
C
Door stops during opening cycle
Door neither opens nor closes
_________________________________________________________________________________________________________________
F
Door stops during opening cycle
__________________________________________________________________________________________________________________
H
Door neither opens nor closes
__________________________________________________________________________________________________________________
L
Door neither opens nor closes
__________________________________________________________________________________________________________________
U
No e
nd-of-travel positions learned
__________________________________________________________________________________________________________________
n
No e
nd-of-travel positions learned
Status display
Operating display
Operating value too low
Button OPEN or CLOSE recognized
Dear customer,
During production the control unit you have
purchased has undergone various checks by
the manufacturer to ensure that it is of
impeccable quality. Should this operator or
parts of it prove to be of no use or limited use
as a result of proven material or manufacturing
defects, we shall rectify this, at our discretion,
through free-of-charge repair or replacement.
We shall not accept any liability for damage as
a result of unsatisfactory fitting and
installation, improper putting into service,
incorrect operation and maintenance,
excessive use and overloading as well as any
Diagnosis / Remedy
Start the learning cycle from the final position at the bottom and open the door completely,
without interruption!
Error occurred during self-testing
Button OPEN or CLOSE are pressed while activating the system.
Button OPEN and CLOSE are pressed simultaneously.
Plausibility error of DES Check the direction of rotation, the motor cable and the quick
.
release mechanism.
Button OPEN or CLOSE pressed simultaneously together with STOP button.
DES: Communication with the DES is disturbed (check plugs, cable and DES).
NES: Restore the factory setting in menu F.
NES: The limit switches OPEN and CLOSE are pressed simultaneously.
DES: Restore the factory setting in menu F and reset the limits of travel.
The motor runtime limitation has tripped. Check the travel path (< 90 sec).
The external safety device at X6 or X8 has tripped (motor thermo-switch, interruption for
the manual mode or spring fracture safety device).
Error occurred during self-testing
Spring breakage detection has been activated. Check springs and if necessary replace
and
programme the end-of-travel positions again.
Opening force limit activated. Eliminate sluggishness or blocking of door. Check springs.
Eliminate the reason for the excessive force being applied, so that the door can be opened
and closed again.
Input Stop at X5 or X9 is interrupted.
Fault at the motor relay identified. Exchange control unit.
The control has recognized operation with DES and is waiting for the end-of-travel
positions to be programmed.
DES recognition process 4 sec after the factory setting.
Door
Door
Door
Terms of Guarantee
alterations or modifications carried out to the
operator and accessory parts by the customer.
The same shall also apply for damage incurred
during transit or as a result of force majeure,
external influences or natural wear as well as
special atmospherical stresses. We cannot
accept any liability following alterations or
modifications of functional parts carried out by
the customer. We must be notified of any
defects immediately in writing; on request the
parts in question are to be made available to
us.
, exchange control unit.
, exchange control unit.
is in the OPEN end-of-travel position
is between end-of-travel positions
is in the CLOSE end-of-travel position
We shall not bear the costs for dismantling
and installation, freight and carriage. If a
complaint is proven to be unjustified, the
customer must bear our costs.
This guarantee is only valid in conjunction
with the signed invoice and commences on
the day of delivery. The manufacturer
guarantees that the product is free of defects.
The warranty is granted for a period of 24
months, in as far as the verification overleaf
has been properly filled out. Otherwise the
warranty shall expire 27 months after the date
of manufacture.