Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than CH.AU is
generally used.
Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is Ch.tr.
If the photocells are type 1 and type 2, the gate enters the phase of
pause only after the detections before both the photocells.
Courtesy lights
This menu allows setting the automatic operating of the courtesy
lights during the opening cycle of the gate.
t.LUC
the relay is enabled at the receiving of a control of start
or pedestrian start; choosing this option, a submenu is
entered – it allows to set the length of the activation of
the relay from 0.0" to 20'0 (default 1'00). At the time
limit, the relay is disabled.
no
the relay of the courtesy lights is not automatically
activated
CiCL
the relay is activated during the motion of the gate;
when the gate stops (closed or open) the relay is on all
the time t.LUC long (set in the submenu t.LUC)
If the option LP.PA is activated, the relay is on also
during the pause time
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver.
tiM
the relay is activated receiving the transmission of the
remote control; it is disabled after the time set for the
parameter t.LUC inside the menu LUCi
Mon
the relay is activated for all the length of the
transmission of the remote control. Releasing the key of
the remote control the relay is deactivated
biSt
the status of the relay changes at each transmission of
the remote control