V2 FORTECO Serie Mode D'emploi page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Brake Function
When a sliding motor is used with a very heavy gate, because of the
inertia, the gate does not block immediately when stopped and its
motion can last for another 10 cm, compromising the working of the
safety devices.
This menu allows enabling the brake function thanks to which it is
possible to block immediately the gate after a control or the intervention
of a safety device.
0
the brake function is never active
1÷10
the brake function is active. Le brake power is proportional to
the set value
Following to an intervention of the safety edge or of the obstacle sensor
or of a STOP control, the braking has always the maximum power,
regardless of the set value (provided that higher than 0) to guarantee a
rapid reversion.
WARNING: each braking entails a mechanical stress to the components
of the motor. We suggest to set the minimum value with which there is
a satisfactory stop distance.
Enabling the obstacle sensor
This menu allows you to regulate the sensitivity of the obstacle
sensor. When the power absorbed by the motor exceeds the level set,
an alarm goes off in the power unit.
If 0.0A is set, the function is disabled.
For information about its working, refer to the dedicated paragraph
(page 40)
Slowing down time
In case this function is enabled, during the last seconds of motion, the
control unit will give motor a reduced power command, to avoid a
strong impact with the stop end. 1'00 is the max. allowed time.
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to measure
both opening and closing times, and to enable it again once the setup
has been carried out. The control unit will automatically consider the
working time delay caused by the slowing down.
• If partial opening time t.APP is shorter than t.AP, there will be no
slowing down during the pedestrian cycle opening.
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase.
PAUSThe gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
Select option PAUS, to set up the "step-by-step" operation logic.
Select option 'no', to set up the 'always open' operation logic.
43

Publicité

Table des Matières
loading