Installation
WARNING: wrong installation can cause
injuries.
The control type T100 R-FU is intended for
!
operation on gates with vertical and
horizontal
movement.
0
Required tools
1
Installing the control unit
2
Opening the control unit cover
Turn off the main switch or pull the mains
plug before opening the top control cover.
Wa
it 1 minute to let any residual voltage at
the motor terminal die down. Protect
against unauthorized starting.
3
Connections
Designation:
J1
Impulse inputs
J2
Safety photocell, two or four-wire or light
array
J3
Closing edge OSE / 8K2 / DW
J4
Emergency-STOP, slack cable, latching
J5
Unassigned
J6
Anti-crash detector
J7
Key switch
J8
Timer inputs
J9
Digital limit switch - motor cable
J10
Connection of frequency converter
J11
Connection of radio receiver
J12
Aerial
J13
Membrane keypad
X1
Mains connection
X2
Mains output L, N (500W / 230V)
X3
Protective conductor contact
X4a
Magnetic brake
X5
Floating relay contact 1,
door status relay
X6
Floating relay contact 2,
door status relay
X7
Door operator
X8a
Light array transmitter output
X8b
24V DC, max. 700mA
4
Mains connection
The control is ready for connection by CEE-Cara 16A
plug and approx. 1m cable as shown in 4a.
The unit must be connected to the mains in
!
accordance with the existing power supply
voltage.
The customer should provide a 10-
amp fused automatic circuit breaker for the
control. If an RCCB is installed it should
comply with class B - universal current
sensitive.
5
Motor connecting lead
All EMC measures (ferrite rings, grounds and
screens) must be performed as shown.
5a Terminal connection diagram for slip-on
motor with DES
5b Terminal connection diagram for slip-in motor
with multiturn
For battery supply of the multiturn transducer plug
the BAT contacts together.
Reprogramming of the end positions is required after
a battery power outage.
6
Impulse generator connection
The gate must remain visible from
the place of operating it.
6a/6b - Connection J1 for external control units
Open, Stop and Close.
6c - Switching sequence Open-Stop-Close, set
value 4 in menu 51.
J1.3 - door half open, J1.4 – door fully open
6d - Open-Stop-Close with lighting
7
Timer inputs
Terminal J8 is intended for operating devices, for AR
service, same as push-pull switch 7a, induction
loops 7b and motion detector 7c. The door closes
automatically at the end of the time set in menu 44.
The open time by the light barrier can be set to a
shorter time in menu 38.
8
Front area monitoring
If the closing speed is greater than 50 cm / s
must the entire door width and depth of
90 cm are monitored on both sides of the
door.
Connection diagram 8 shows the run-up monitoring
by motion and present detectors Condor.
9
Safety edge connection
Door connection socket with slack rope switch or
break-away sensor and slip door contact 8.
Select the setting of the safety edge connection in
menu 35:
Door connection socket with slack rope switch and
slip door contact 8.
- Optical closing edge OSE - only OSE from Fraba or
Witt are permitted
- Electrical safety edge 8K2 with a termination
resistor of 8.2 kOhm (value = 1)
- Electrical safety edge 8K2 in series connection with
slack rope and wicket door switch (value = 3)
- Pressure wave edge and switch with a loop
resistance of 8.2 kOhm (value = 2)
10
Connection for light array
The following light arrays can be connected.
9a
Light array with testing
For this, set value 5 in menu 36.
9b
Light array with OSE interface
For this, set value 0 in menu 36.
11
Photocell connection
10a Two-wire photocell Ls2
10b Four-wire photocell LS5 with self-testing
10c Reflection photocell
If in the menu the frame-fitted photocell has been
selected, the next time the door closes the control
unit automatically initiates a learning run to detect
the position. E10 will be disdplayed.
During this process the closing procedure
must not be interfered with, otherwise the
wrong position could be recorded.
12
Anti-crash sensor
Input J6 detects when the curtain is off guide and
starts an automatic threading up.
One-way light barrier with relay output 11a, with
transistor output 11b.
13
Emergency-STOP connection
Use input also for spring break switch.
14
Key switch / pull button connection
When using a key switch / pull button, the desired
function in menu 50 should be selected.
15
Radio remote control
Slip receiver module (optional) on J11 and connect
the antenna. Program the handheld transmitter.
16
Relay output
2 change-over contacts:
max. 250VAC / 2A or 24VDC / 1A.
24V-output X8: max. 700mA
Selecting the relay function in menu 45 and 46.
15c Interlocking of two doors (lock circuit) .
Menu 50 value 2 and menu 46 value 1.
15c Interlocking of three doors (lock circuit) .
Menu 50 value 2 and menu 46 value 1.
GB