15. Light Kit LED Driver Replacement
15.8
Squeeze and unclip the motor AC power connector from
the Light Kit LED Driver connector (Figure 47).
Squeeze and unclip the motor DC power connector
from the Light Kit LED Driver connector (Figure 47).
15.9
Remove the two Phillips head screws from the Old Light
Kit LED Driver (Figure 48).
Retain the screws for future reinstallation.
Gently pull up on the Light Kit LED Driver. Remove the
Driver from the motor housing (Figure 48).
Discard the Old Light Kit LED Driver in the correct
recycle bin.
15.10
Place the New Light Kit LED Driver into the motor
housing, aligning it directly where the Old Driver had
been (Figure 49).
Install the New Light Kit LED Driver to the motor
housing using the two screws previously removed
(Figure 49).
MOTOR DC POWER
CONNECTOR
MOTOR AC POWER
CONNECTOR
LIGHT KIT LED
DRIVER AC POWER
CONNECTOR
Figure 47
Figure 48
Figure 49
30
(Continued)
LIGHT KIT LED DRIVER
DC POWER CONNECTOR
LIGHT KIT
LED DRIVER
REMOVE & RETAIN
PHILLIPS HEAD
SCREWS (2)
OLD LIGHT
KIT LED
DRIVER
MOTOR
HOUSING
REPLACE PHILLIPS
HEAD SCREWS (2)
NEW LIGHT
KIT LED
DRIVER
MOTOR
HOUSING