6. Optional Installation No-Light Plate Assembly
6.3
Disengage the fan motor assembly 2-pin wire connector
from the 2-pin wire connector of the Light Kit Assembly
(Figure 23).
Store Light Kit Assembly in a safe location for future
installation.
Reinstall the #6-32 x .375" pan head screw into the
Light Kit Adapter.
Securely tighten the three #6-32 x .375" pan head
screws.
A spare Light Kit Assembly #6-32 x .375" pan head
screw is in the parts bag, if needed.
6.4
Carefully tuck all the wires and connector into the Light
Kit Adapter.
Place the no-light plate into the opening of the Light Kit
Adapter, aligning the three flat areas on the top edge of
the no-light plate with the three raised dimples on the
Light Kit Adapter and turn the plate clockwise until it
NOTE: The no-light plate is equipped with an
stops (Figure 24).
interference device that will not allow it to be
installed if the light kit assembly is not removed.
NOTE: Periodically check that the no-light plate is
seated fully clockwise in Light Kit Adapter.
REINSTALL LIGHT
KIT ADAPTER PAN
HEAD SCREW
FAN MOTOR ASSEMBLY
2-PIN CONNECTOR
LIGHT KIT ASSEMBLY
2-PIN CONNECTOR
Figure 23
ROTATE CLOCKWISE
Figure 24
14
(Continued)
NO-LIGHT PLATE
INTERFERENCE DEVICE
L IGHT KIT
ADAPTER
RAISED
DIMPLES (3)
NO-LIGHT PLATE
FLAT AREA OF NO-LIGHT
PLATE (3)

Publicité