Télécharger Imprimer la page

Active Olivator E1200 L Instructions Pour L'utilisation Et Manutention page 25

Publicité

Les langues disponibles

Les langues disponibles

easily, use the tool S (included) and a hammer to push it slowly out from its housing in the direction
indicated by the arrow.
Fix the new tine in the support Y and then in the housing P, pushing it down eventually using a hammer.
Screw the locking nut up to the limit.
8.
ORDINARY MAINTENANCE
Codes E1200L-E1200XL E4800L-E4800XL E4800L HD-E4800XL HD E4800BPL HD-E4800BPXL HD
MAINTENCANCE
Maintenance has to be carried on by qualified personnel, following the instructions of this manual and
using only original spare parts. User has to follow all the applicable safety laws, using as necessary the
right protective equipment.
IMPORTANT : Every 50 working hours, the internal mechanisms of the head have to be
lubricated with grease for high temperatures. The points have to be lubricated according to
the picture F.
Follow the instructions in fig. F for the grease input.
Rotate the head in order to have access to the rear part (fig. F.1) and identify the two holes V.
Unscrew the two screws W, as indicated in fig. F.2. Using one needleless syringe, as indicated in
fig. F.3, put the grease inside using the holes V. Reassemble the screws and tighten them down.
LONG TERM MAINTENANCE
In case of long lasting inactivity periods, the machine has to be carefully cleaned and then protected
from dust and humidity in a dry place clear from direct sun and freeze. The battery shall not be
connected with the machine as is it is not in use. It shall be stored with full charge and re-charged every
three months.
CHECKS AND ANOMALIES
COMPONENT
Clamps and connectors
Power cable
Tines
E1200L- E1200XL
ANOMALIES (
By pressing the
start button the
motor does not
turn on or turns
on slowly.
ANOMALIES
(E4800L - E4800XL E4800L HD - E4800XL HD
E4800 BPL HD - E4800 BPXL HD)
By pressing the
All the LEDs of the power supply are off.
start button the
motor does not
turn on.
LEDs are regularly ON
LEDs are regularly ON
ALARM red light ON
ALARM red light ON (single impulse)
ALARM red light ON (multiple impulses)
ACTIVE S.r.l. - Via Delmoncello, 12 - 26037 San Giovanni in Croce - CR
Tel. 0375/94172
www.active-srl.com
)
email: info@active-srl.com
25
ACTION
Check the integrity and efficiency of
the contacts
Check that the cable is not twisted
Check the integrity and locking
CAUSE
Damaged clamps or connectors
Damaged cables
Damaged motor
Empty battery
Low battery
Other
CAUSE
Damaged clamps or connectors
Interrupted fuse
Damaged electronic power supply
Damaged cables
Damaged motor
Empty battery
Low battery
Anomaly
Ref. Fig.F
FREQUENCY
Every day
Every day
Every day
SOLUTION
Replace
Replace
Replace
Replace or recharge
Recharge
Contact the service
point
SOLUTION
Replace
Replace
Replace
Replace
Replace
Replace or recharge
Recharge
Contact the service
point

Publicité

loading

Ce manuel est également adapté pour:

Olivator e1200 xlOlivator e4800 lOlivator e4800 xlOlivator e4800 l hdOlivator e4800 xl hdOlivator e4800 bp l hd ... Afficher tout